Getting Mike Power Supply setting 
Format  /api/param?audio.input(1).powersupply.status 
Example of response  audio.input(1).powersupply.status=on&200 OK 
Interpretation  Acquire mike power supply setting. "on" or "off" is returned. 
Allowed users  admin, operator, user 
 
Setting Mike Power Supply 
Format  /api/param?audio.input(1).powersupply.status=data 
Example  /api/param?audio.input(1).powersupply.status=32 
Example of response  audio.input(1).powersupply.status&200 OK 
Interpretation  Change mike power supply setting. Specify "on" or "off". 
Allowed users  admin, operator 
 
 
11. JVC API for Alarm 
These APIs are related to alarm settings. Same functions are shown on the Alarm page of the WEB setting page. 
Refer to the instruction manual for details on the Alarm page. 
 
Getting On/Off of Alarm Action 
Format  /api/param?application.event(Number).status 
Example  When Getting the on/off status of alarm action No. 1 
   /api/param?application.event(1).status 
Example of response  application.event(1).status=on&200 OK 
Interpretation  Acquire the on/off status of the alarm action for the specified alarm action number. 5 alarm actions, 
1 periodic FTP assigned to No.6, 1 pre/post FTP assigned to No.7, 1 SD Card constant recording assigned to 
No.8, and 1 SD Card alarm recording assigned to No.10 are available, so alarm action number can be 1 to 8 and 
10. Note that alarm numbers are different from the alarm input pin numbers. Either on or off is returned. 
Allowed users  admin, operator 
 
Setting On/Off of Alarm Action, or Enabling Changes to Alarm Action 
Format  /api/param?application.event(Number).status=data 
Example  When setting alarm action No. 1 to off 
  /api/param?application.event(1).status=off 
Example of response  application.event(1).status&200 OK 
Interpretation  Set the alarm action of the specified alarm action number to on/off, or enable changes to the alarm