Axis Communications p1357-e User Manual

Page of 74
AXIS P1357–E Network Camera
Technical Specifications
Function/group
Item
Specifications
Languages
German, French, Spanish, Italian, Russian, Simplified Chinese, Japanese, Korean,
Portuguese
Warranty
Axis 3–year warranty and AXIS Extended Warranty option see www.axis.com/warranty
Connectors
I/O Connector
4–pin terminal block
For an example diagram, see Connection Diagrams on page 72.
Function
Pin
Notes
Specifications
0 V DC (-)
1
DC output
2
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
3.3 V DC
Max load = 50 mA
Digital Input
3
Connect to pin 1 to activate, or leave floating (unconnected)
to deactivate.
0 to max 40 V DC
Digital Output
4
Connected to pin 1 when activated, floating (unconnected)
when deactivated. If used with an inductive load, e.g. a relay,
a diode must be connected in parallel with the load, for
protection against voltage transients.
0 to max 40 V DC, open drain,
100 mA
Power Connector
2-pin terminal block for DC power input. Use a Safety Extra Low Voltage (SELV) compliant
limited power source (LPS) with either a rated output power limited to ≤100 W or a rated output
current limited to ≤5 A.
Audio Connector
3.5 mm audio connectors
(stereo)
1
2
3
1 Tip
2 Ring
3 Sleeve
Audio Input
Microphone/Line in
Ground
Audio Output
Line out (mono)
Ground
71