Bosch VBN-5085 User Manual

Page of 52
DINION 5000 AN
Configuration | en
25
Bosch Security Systems
Installation Manual
AM18-Q0644 | v1.0 | 2013.03
5.5.2
Exposure submenu
Item
Selection
Description
ALC level
-15 to +15
Selects the video level range. A 
positive value is more useful for low-
light conditions; a negative value is 
more useful for very bright 
conditions.
Some ALC adjustment may improve 
scene content when Smart BLC is 
enabled.
ALC speed
Slow, 
medium, fast
Adjusts the speed of the video level 
control loop. For most scenes it 
should remain at the default value.
Shutter
AES, FL, Fixed
AES (auto-shutter) - the camera 
automatically sets the optimum 
shutter speed.
FL - flickerless mode avoids 
interference from light sources 
(recommended for DC-iris lenses 
only).
FIXED - allows a user defined shutter 
speed.
Default (AES) 
shutter 
or
Fixed shutter
1/50 (PAL) 
1/60 (NTSC),
1/100 (PAL) 
1/120 (NTSC),
1/250, 
1/500, 
1/1000, 
1/2000, 
1/4000, 
1/10K,
1/100K 
In DEFAULT (AES) mode, the camera 
tries to maintain the selected shutter 
speed as long as the light level of the 
scene is high enough.
In Fixed mode, selects shutter 
speed.