Avaya R300 User Manual

Page of 112
DEFINITY Enterprise Communication Server Release 9
Getting Started with the Avaya R300 Remote Office Communicator  
Issue 1
November 2000
DEFINITY Administration for the Avaya R300 
60
Set up signaling group 
4
Set up signaling group 
Each Avaya R300 has its own listen port and signaling group. Set up a new trunk group, or 
use an existing trunk group administered for H.323 signaling. 
Instructions
Signaling Group
Set up the signaling group for remote office: 
1. Type 
add signaling-group
 
<signaling group number or next>
and press 
ENTER
 to display the Signaling Group screen. 
Screen 15.
Signaling Group
2. On the signaling group screen, fill in the following fields:
Group Type: type 
H.323
.
Remote Office: type 
y
.
Near-end Node Name: assign the node name assigned to the C-LAN that 
supports this Avaya R300.
Far-end Node Name: type the node name assigned to the remote office.
Near-end Listen Port: type a port number in the 5000-9999 range.
Far-end Listen Port: type 1720.
3. Press 
ENTER
 to save your changes.
add signaling-group 6
 
Page 1 of 5
    
SIGNALING GROUP
Group Number
6
Group Type:
H.323
Remote Office?
y
Max Number of NCA TSC: ___
Max number of CA TSC:
___
Trunk Group for NCA TSC:
___
Trunk Group for Channel Selection:
6
Supplementary Service Protocol: _
Near-end Node Name:
clan
Far-end Node Name: remote office 6
Near-end Listen Port:
5001
Far-end Listen Port:1720
LRQ Required? _
Calls Share IP Signaling Connection?
_
RRQ Required? y
Bypass If IP Threshold Exceeded?
_
Direct IP-IP Audio Connections?
_
Interworking Message: ________