Avaya R300 User Manual

Page of 112
DEFINITY Enterprise Communication Server Release 9
Getting Started with the Avaya R300 Remote Office Communicator  
Issue 1
November 2000
Avaya R300 Administration 
88
Resetting the Avaya R300 
5
When you upload this remote configuration information, keep in mind the following:
The Avaya R300 reads Dialout-Framed-User entries with the password 
ascend
.
The Upd Rem Cfg command does not update the terminal-server banner or list of 
Telnet hosts if the Remote Conf parameter is set to No.
If the Ascend-Authen-Alias attribute is defined in RADIUS, the Upd Rem Cfg 
command also updates the Avaya R300 system name used when establishing PPP 
calls.
NOTE:
In some cases, you might wish to update the Avaya R300 unit’s routing 
tables when connecting to a user whose profile includes 
Service-Type=Framed
. In this case, set the Framed-Route attribute in 
an incoming user profile to specify the user’s IP address and subnet mask in 
the 
host_ipaddr
 and 
subnet_mask
 arguments. The route you specify 
in this manner exists only during the time the call is online. When you enter 
a nonzero router address for 
router_ipaddr
 and it is different from the 
caller’s address, the static route of a dial-in frame persists even after the 
connection goes offline.
Example: 
This example shows two RADIUS pseudo-user profiles defining global static IP routes:
route-1 Password=ascend Service-Type=Outbound
Framed-Route=10.0.200.33/29 10.0.200.37 1 n lala-gw-out
Framed-Route=10.0.200.50/29 10.0.200.37 1 n lala-gw-out
Framed-Route=10.0.200.47/29 10.0.200.49 1 n nana-gw-out
route-2 Password=ascend Service-Type=Outbound
Framed-Route=11.0.200.33/29 11.0.200.37 1 n zzz-gw-out
Framed-Route=12.0.200.47/29 11.0.200.49 1 n kk-gw-out
Resetting the Avaya R300
The Avaya R300 unit needs to be reset if you upload a new system software configuration 
(not a new Avaya R300 profile configuration). You can reset the Avaya R300 unit in one 
of the following ways:
Choose System >Sys Diag > Sys Rest from the VT100 menu interface.
Type 
reset
 at the diagnostic prompt.
Power cycle the unit by pulling the plug out of the outlet and then plugging it back 
into the outlet.
NOTE:
Power cycling is not the preferred method of shutting down the Avaya R300. 
The system does some clean-up with DEFINITY when reset using one of 
the other methods.