en | Installation
DinionHD 720p IP Camera
AR18-10-B013 | v1.52 | 2011.06
Installation and Operation Manual
Bosch Security Systems
5.5
Alarm and relay connector
Figure 5.6
Alarm and relay connector pins
Alarm Input
AWG 26-16 max.(0.13-1.5 mm
2
); cut back 5 mm (0.2 in) of 
insulation.
Impedence: Internal pull-up 10 kOhm to +5 VDC.
Input voltage range: -5 VDC minimum to 40 VDC maximum.
Input voltage treshold: low voltage 0.8 V maximum, high 
voltage 2.4 V minimum.
Configurable as active low or active high.
Use the alarm input to connect external alarm devices such as 
door contacts or sensors. A zero potential make or break 
contact can be used as the actuator (use a bounce-free contact 
system).
Relay output
Max. wire diameter AWG 22-28 for both stranded and 
solid; cut back 5 mm (0.2 in) of insulation.
Output relay switching capability: Max voltage 30VAC or 
+40 VDC. Max 0.5 A continuous, 10 VA.
Max. 42 V allowed between camera ground and each of the 
relay pins.
Pin
Alarm socket
1
Alarm in 1
2
Alarm in 2
3
Relay out contact 1
4
Ground
5
Ground
6
Relay out contact 2
Alarm
1
2
3
4
5
6
5 mm 
(0.2 in)