Set the Boundary Width and Test the 
Receiver Collar
With the Boundary Wire in place and properly connected, it 
is time to set the containment fi eld and test the system.
CAUTION
The Receiver Collar should NOT be on 
your dog when the system is tested.
Note: The Receiver Collar is waterproof, which can make the tone 
hard to hear.
The fl ashing Test Light when held to the Contact Points 
indicates the Receiver Collar is delivering Static Correction. 
To best utilize the automatic Run-Through Prevention
feature, the containment Boundary Width should extend
6A
at least 6 to 10 feet on each side of the Boundary Wire (total Boundary Width of 
12 to 20 feet).
Apply Power to the Fence Transmitter 
1. 
with the supplied Power Adapter. 
Set the Boundary Width Control 
2. 
Switch (located on the side of the 
Fence Transmitter) (6A) to the A, B, or 
C setting based on the total length of 
Boundary Wire  used.  Setting B is used 
for most properties. The following table 
will indicate the proper setting.
Amount of Wire
Setting
Greater than 2400 feet
A
Up to 1300 feet
B
1300 to 2400 feet
C
The width of the containment fi eld is adjusted using the transmitter’s
3. 
Boundary Width Control knob. Turn the knob counter clockwise until the 
alarm sounds and the Loop Indicator Light is no longer lit. Turn the knob 
clockwise and increase by 2 numbers. The alarm should turn OFF and the
light should turn ON.
CAUTION
The receiver collar should not be on your dog when the system is 
tested. Your pet may receive an unintended correction.
Place battery in Receiver Collar and turn ON. The Receiver Collar will cycle 
4. 
through the Static Correction and Battery Status feature as described in Step 
5. To identify the Warning and Static Correction Zones make sure the Receiver 
Collar is set at level 5 (see Step 5).
Test the Boundary Width of the system by selecting a section of straight Boundary 
5. 
Wire that is at least 50 feet long. Start inside the center of the containment fi eld.
Place the Test Light Tool 
6. 
Contacts on the Contact 
Points on the Receiver Collar 
(6B,6C). Hold the Receiver 
Collar at your dog’s neck 
height with the Contact 
Points pointing up (6D) and 
the Correction Level Button
Test Light Contacts
6B
6C
facing the Boundary Wire. Slowly 
walk toward the Boundary Wire until 
you hear the warning tone(6E). When 
you hear the warning tone, you have 
identifi ed the Boundary Width distance 
(Static Correction Zone). 
6D
Boundary  
Wire 
6E
Step
6