Plasmon LF 8600 User Manual

Page of 113
 
97663032 A
 Page 17
MEDIA ENVIRONMENTAL CHARACTERISTICS
The following table presents the LM 8000 Media environmental characteristics.
Table 3. 
Media Operation, Storage and Transportation Environments
SHOCK AND VIBRATION
The following table lists the conditions and limits for shock and vibration.
Table 4. Shock and Vibration Criteria and Limits
1  With media removed.
2  In LMS - approved packaging.
3  Shock repetition rate should be limited to allow mechanical system transients to subside between pulses.
SPECIFICATION
OPERATION AND 
SHORT TERM 
STORAGE
(2 years maximum)
TRANSPORTATION
(2 weeks maximum)
LONG TERM
STORAGE
Temperature
10°C to 47°C
50°F to 116.6°F
-20°C to +55°C
-4.0°F to 131.o°F
10°C to 30°C
50°F to 86.0°F
Relative Humidity
(no condensation)
5% - 80%
5% - 90%
5% - 80%
Wet Bulb Temperature
26°C max.   (78.8°F)
26°C max.   (78.8°F)
26°C max.   (78.8°F)
Temperature Gradient
10°C/hr max.
 (18.0°F/hr  max.)
31°C/hr max. 
(55.8°F/hr max.)
5°C/hr max. 
(9.0°F/hr max.)
Air Pressure
N/A
N/A
N/A
Solar Radiation
N/A
Case to be kept closed
Not to be stored in direct 
sunlight
CONDITION
OPERATING
NONOPERATING
1
STORAGE/TRANSIT
2
Swept Vibration
(Bidirectional)
1 Octave/Min
5 to 250 Hz  0.1 g Peak, 
250 to 500 Hz
0.25 g Peak
5 to 44 Hz, 0.03 in
Double Amplitude,
44 to 500 Hz 
3.0 g Peak
5 to 44 Hz, 0.03 in
Double Amplitude,
44 to 500 Hz 
3.0 g Peak
Shock 
3
(Host Retries May Be 
Required and Drive 
Performance May 
Degrade During Test
10 - msec Half Sine Pulse 
of  2.5 g Peak, with pulses 
applied every 3 sec
Unpacked (3 Axis)
5 - msec Half Sine 
Pulse of 20 g Peak
Packed on Pallet
46 - cm (18 - in)
Drop Test Flat