CONNECTOR VERIFICATION
Prior to powering on the system:
1. Verify proper termination at the host adapter, if applicable.
2. Verify proper termination at the last LF 8600 on the bus, if applicable.
CAUTION
Ensure that the foam shipping block has been removed from the
shuttle assembly before powering on the LF 8600.
RACK MOUNT CONFIGURATION DE-INSTALLATION
To de-install the LF 8600 Rack Mount configuration:
1. Remove the cabinet trim panel by grasping the panel at the top and pulling outwards. This 
action pries the ball studs from the keeper holes.
2. Remove the right or left lateral Support Angle that anchors the Chassis to the adjacent cabinet 
rail by unfastening the two M4 screws and optional standoffs. Remove other fastening 
hardware anchoring the Support Angle to the rail.
3. Lift the slide releases and pull the LF 8600 all the way out of the cabinet.
WARNING
If two drives have been installed in the rack, ensure that only one
drive is extended at a time.