14.1 Faults
Faults
cause/steps
no display: lamp not ignited and fan of the
illumination unit not running
The equipment is not connected to power sup-
ply. It must be supplied with suitable voltage
(see
Power switch is off. Switch on power switch.
See 
The cover of the lamp housing is not installed
correctly, and the micro-switch in the housing
interrupts power supply. The cover sheet must
be fixed (see 
display is upside-down
change the configuration:
To change the configuration of the projector,
proceed as follows:
Press 
ENTER
 to start up the adjustment
mode.
Press the cursor key 
up
 or 
down
 to select
'Installation'
.
Press 
ENTER
 to display the 
Installation
menu
.
Press the cursor key 
up
 or 
down
 to select
'Configuration'
.
Press 
ENTER
 to display the 
Configuration
menu
. The actual installed configuration
will be highlighted.
Press the cursor key 
up
 or 
down
 to select the
corresponding configuration.
the display is dark though the lamp is ignited
there is no signal applied. Check the input source
and the connections
A
TLAS 
CS4 can not be controlled via the
RCU
point the front of the 
RCU 
directly to the sensor
on the screen. When using the wireless remote
control, make sure you are within the effective
operating distance (30m, 100ft in a straight line).
The remote control unit will not function prop-
erly if strong light strikes the sensor window or
if there are obstacles between the remote control
unit and the IR sensor.
Table 14-1