3M 250/900 User Manual

Page of 8
78-0013-6978-0-B
 5
250 µm fi ber
2.6  Close the funnel door and bow start door on the fiber 
holder. Again ensure that the guide funnel is pushed 
completely forward to the end of the fiber holder. 
Pull the fiber back until the fiber tip is flush with 
the end of the funnel. To verify the cleave length is 
still correct, all coatings should align with the hole 
located in the funnel. Close the back clamp. 
Note: for semi-tight buffer fi ber, the 250 µm coating 
may protrude up to 1 mm past the 900 µm buffer. If 
necessary, re-strip, clean and cleave the fi ber to meet 
length requirements.
Fiber coatings
2.7  Place fiber holder in assembly base and slowly slide 
fiber holder forward, toward the connector.
Note: Allow 10 seconds for this movement from the 
time the fi ber begins to enter the boot on the connec-
tor until the fi ber holder bottoms out in the assembly 
base.
10 seconds or a rate of 3 mm/sec
Guide funnel door opened by 
cam on the assembly base
Fiber bow should start when the white line on 
fiber holder aligns with the “BOW START” 
mark on the assembly base
2.8  While slowly sliding the fiber holder toward the 
connector, a bow should start to form in the fiber 
when the white line on the fiber holder aligns with 
the white BOW START line on the assembly base. 
If a bow is not seen, slide the fiber holder back. If 
a bow is not seen, or if a bow is seen before the 
two white lines meet, slide the fiber holder back. 
Re-strip, clean and cleave the fiber, and begin the 
termination process again.
Fiber bow
Release lever
Guide funnel stops when 
ear contacts release lever
No gap between fiber 
holder and actuation 
when fully inserted
2.9  Continue to slowly slide fiber holder towards 
connector until it stops. Verify fiber bow again. 
Note: The fi ber will bow and lift the middle cover 
for rigid fi bers and remain closed for 250 µm and 
especially fl exible 900 µm fi bers. This ensures proper 
fi ber insertion force.
Guide funnel
Place fiber tip here
Hole