RS-232C command table
How to read the command table
Command:
Command field (See page 29.)
Parameter:
Parameter field (See page 29.) 
* :
Enter the number in brackets in the settings
 :
Enter a space
TIPS
•  In the standby mode, the only command that is used is POWER CONTROL.
The operation of commands not indicated in the table below is not guaranteed.
Function
Command
Parameter
Settings
POWER 
CONTROL
P O W R 0
Switches to standby mode.
P O W R 1
Enters the power ON state.
INPUT MODE 
SELECTION
I
T G D
Toggle change for input mode.
I
A V D
*
Change to the INPUT1 to 6 terminal. (1 - 6)
PICTURE MODE 
SELECTION
A V M D 0
Toggle change for PICTURE MODE.
A V M D 1
STANDARD
A V M D 2
MOVIE
A V M D 5
DYNAMIC
A V M D 6
DYNAMIC (FIXED)
A V M D 7
PC
VOLUME
V O L M *
*
*
Set the volume. (0 - 100)
(When AUDIO OUTPUT is set to VARIABLE, the Parameter (0 - 100)
is supported for the setting value (-100 - 0).)
SCREEN
H P O S
*
*
*
Adjust the horizontal position of the image. (000 - 180) (PC (INPUT6))
V P O S
*
*
*
Adjust the vertical position of the image. (000 - 120) (PC (INPUT6))
C L C K
*
*
*
Set the frequency of the sampling clock of the picture. (000 - 180)  
(PC (INPUT6))
P H S E
*
*
*
Adjust the phase of the sampling clock of the picture. (000 - 015)  
(PC (INPUT6))
SCREEN SIZE*
W I
D E 0
Toggle change for screen size.
W I
D E 7
NORMAL
W I
D E 9
WIDE
W I
D E 1
0
Dot by Dot
W I
D E 1
1
UNDERSCAN
MUTE
M U T E 0
Toggle between mute and unmute.
M U T E 1
Mute.
M U T E 2
Unmute.
*  When the screen size is changed automatically using HDMI AUTO WIDE, the current value is not an auto sized value but a
value set manually.