Sharp PN-K322B User Manual

Page of 41
26
E
You can return the settings to their factory-preset values and 
restrict operations.
1.  Hold down the [MENU/ENTER] button and [INPUT/
RETURN] button at the same time until “F” appears in 
the screen, and then press the [MENU/ENTER] button 
and [VOL-/   ] button at the same time while “F” 
appears.
 

OFF
UNLOCKED
ON 1
ON
OFF
OFF
FUNCTION
ALL RESET
ADJUSTMENT LOCK
RS-232C
OSD DISPLAY
LED
TEMPERATURE ALERT
STATUS ALERT
END…[RETURN]
OK…[ENTER]
2.  Select and set the items.
ALL RESET
Resets the settings to the factory default settings.  
Select ALL RESET, and then press [MENU/ENTER] 
button.
After initialization, turn the main power switch off and 
then back on.
ALL RESET ......Resets all the settings to the factory 
default settings.
CANCEL ...........Go back without resetting.
ADJUSTMENT LOCK
You can disable operations on the monitor buttons.
OFF ...Enables operation.
ON 1 ..Disables all operations other than turning power 
on/off and FUNCTION.
ON 2 ..Only the FUNCTION operation is enabled. 
Disables all operations other than FUNCTION (not 
even power on/off).
RS-232C
Specifies whether to allow control via RS-232C. (See 
page 27.)
OSD DISPLAY
Shows/hides the menu, modes and messages.
The FUNCTION screen cannot be hidden.
ON 1 .............. Shows all menus, modes and messages.
ON 2 .............. Hides messages automatically displayed 
by the display. Shows messages during 
operation.
OFF ............... Hides all menus, modes and messages.
LED
Specifies whether to light the power LED.
Initialization (Reset)/Functional Restriction Setting (FUNCTION)
TEMPERATURE ALERT
Selects the notification method for an abnormal 
temperature.
OFF .............. Do not notify about an abnormal 
temperature.
OSD & LED .. When an abnormal temperature is 
detected, the power LED flashes in red 
and green alternately and the screen 
displays a message: TEMPERATURE.
LED............... When an abnormal temperature is 
detected, the power LED flashes in red 
and green alternately.
STATUS ALERT
Selects the notification method for a hardware error.
OFF .............. Do not notify about the error.
OSD & LED .. When a hardware error is detected, the 
power LED flashes in red and the screen 
displays a message: STATUS [xxxx].
LED............... When a hardware error is detected, the 
power LED flashes in red.
3.  Press [INPUT/RETURN] button to return to the normal 
screen.
TIPS
•  When both abnormal temperature and hardware error are 
detected, the hardware error notification overrides.
•  If TEMPERATURE ALERT or STATUS ALERT is set to 
OSD & LED, alert messages will appear even if the OSD 
DISPLAY is set to ON 2 or OFF.
•  If TEMPERATURE ALERT or STATUS ALERT is set to LED 
or OSD & LED, the LED lights even if the LED function is 
set to OFF.