Controlling the Monitor with a PC (RS-232C)
You can control this monitor from a PC via RS-232C (COM 
port) on the PC.
You can also connect multiple monitors via a daisy chain by 
using a PC. By assigning ID numbers to each monitor (see 
page 33), you can make input mode selection/adjustment or 
can check the status of a specific monitor.
TIPS
•  To control the monitor via RS-232C, set STANDBY MODE 
to STANDARD.
PC connection
n
One-to-one connection with a PC
Connect with RS-232 straight cable between the PC’s COM 
port (RS-232C connector) and the RS-232C input terminal on 
the monitor.
RS-232 straight cable
(commercially available)
To COM port
PC
RS-232C
input terminal
n
Daisy chain connection…
Advanced operation
PN-Y325 monitors can be connected together in a daisy chain 
connection. 
Connect with RS-232 straight cable between the PC’s COM 
port (RS-232C connector) and the RS-232C input terminal on 
the first monitor. 
Next, connect RS-232 straight cable to the first monitor’s 
RS-232C output terminal and to the second monitor’s 
RS-232C input terminal. Connect in the same way to the third 
and subsequent monitors.
Up to 25 monitors can be connected. (Depending on the 
length of the cable used and the surrounding environment.)
RS-232C
input terminal
RS-232C
output terminal
To COM port
PC
First monitor
Second monitor
RS-232 straight cables 
(commercially available)
Communication conditions
Set the RS-232C communication settings on the PC to match 
the monitor’s communication settings as follows:
Baud rate
9600bps
Stop bit
1 bit
Data length
8 bits
Flow control
None
Parity bit
None
Communication procedure
n
Command format
When a command is sent from the PC to the monitor, the 
monitor operates according to the received command and 
sends a response message to the PC.
C1  C2  C3  C4  P1  P2  P3  P4 
Return code 
Command field  
(4 prescribed  
alphanumerical characters) 
Parameter field 
(4 character string comprised of: 
0-9, +, -, space, ?)
 Example:  VOLM0030
 VOLM 
   30
*  Be sure to input 4 characters for the parameter. Pad with 
spaces (“ ”) if necessary.  
(“   ” is a return code (0D
H
, 0A
H
 or 0D
H
))
Wrong  : VOLM30
Right  : VOLM     30
Do not use spaces for DATE. Specify parameters using a 
specified number of characters.
If a command has “R” listed for “DIRECTION” in the 
“RS-232C command table” on page 36, the current value can 
be returned by using “?” as the parameter.
 Example:
VOLM ? ? ? ?
From PC to monitor (How much 
is current volume setting?).
30
From monitor to PC (Current 
volume setting: 30).
*  If an ID number (see page 33) has been assigned 
(For example, ID number = 1).
VOLM 
?
From PC to monitor.
30   001
From monitor to PC.