NSR-1000 Series v1.1.1 Release Note 
values different from actual ones when making configurations for the 
cameras/camera servers shown below (V11R:483) 
   SNC-RH series 
   SNC-RS series 
   SNT-EP series 
   SNT-EX series 
In this case, perform the adjustment of the detection area size while viewing 
on the frame in the configuration screen. 
 
・ 
When parameters in the Video setting tab are changed while recording, it will 
affect the recording like the followings. (V11N:155) 
 
Manual Record 
    All parameters in the Monitoring are reflected to the recording. 
 
Schedule Record, Event/Alarm Record 
  In case Codec is changed 
        The change is reflected to the recording. 
    By this change, if a combination of settings in the Schedule tab become 
inappropriate, settings in the Video tab are reflected to the recording 
automatically. 
        However the internal change will not reflected in the Schedule tab. 
 
  In case Size/Bitrate/Framerate is changed 
    ・  In case "Device Setting" is set in the Schedule tab 
      The change is reflected to the recording. 
    ・  In case settings are already specified in the Schedule tab 
      Settings in the Schedule tab are given priority to the Video tab. 
            And the settings are reflected when the schedule starts. 
 
・ 
When registering many (e.g. 64) cameras with Multiple Camera Registration at 
one time, NSR performance becomes worse for a while. In such condition, if you 
log off NSR and log on again, it may fail. Please wait several minutes after 