Sony KMS-2608/J1N User Manual

Page of 64
27
KMS
260B
20101
H0576
Iop = 57.6 mA in this case
Iop (mA) = Digital voltmeter reading (mV)/1 (
Ω
)
7. Then, rotate the  AMS  knob and display “LDPWR CHECK”.
8. Press the  YES  button once and display “LD 0.9 mW $ 
”.
Check that the reading of the laser power meter become 0.85 to
0.91 mW.
9. Press the  YES  button once more and display “LD 7.0 mW $
”. Check that the reading the laser power meter and digital
volt meter satisfy the specified value.
Note down the digital voltmeter reading value.
Specified Value :
Laser power meter reading : 7.0 ± 0.2 mW
Digital voltmeter reading : Optical pick-up displayed value ± 10%
(Optical pick-up label)
10. Press the  MENU/NO  button and display “LDPWR CHECK”
and stop the laser emission.
(The  MENU/NO  button is effective at all times to stop the
laser emission.)
11. Rotate the  AMS  knob to display “Iop.Write”.
12. Press the  YES  button. When the display becomes
Ref=@@@.@ (@ is an arbitrary number), press the  YES  button
to display “Measu=@@@.@” (@ is an arbitrary number).
13. The numbers which can be changed will blink. Input the Iop
value noted down at step 9.
To select the number : Rotate the  AMS  knob.
To select the digit : Press the  AMS  knob
14. When the  YES  button is pressed, “Complete!” will be displayed
momentarily. The value will be recorded in the non-volatile
memory and the display will become “Iop Write”.
Note 1: After step 4, each time the  YES  button is pressed, the
display will be switched between “LD 0.7 mW $ 
”, “LD
6.2 mW $ 
”, and “LD Wp 
 $ 
”. Nothing needs
to be performed here.
(For details of the method for checking
this value, refer to “5-8. Recording and
Displaying IOP Information”.)
5-12. TRAVERSE  ADJUSTMENT
Connection :
Adjusting Procedure :
1. Connect an oscilloscope to CN105 pin 4 (TE) and CN105 pin
6
 (VC) of the BD board.
2. Load a test disc (MDW-74/GA-1). (Refer to Note 1.)
3. Press the  M  button and move the optical pick-up outside the
pit.
4. Rotate the  AMS  knob and display “EF MO ADJUST”.
5. Press the  YES  button and display “EFB = 
 MO-R”.
(Laser power READ power/Focus servo ON/tracking servo OFF/
spindle (S) servo ON)
6. Rotate the  AMS  knob so that the waveform of the oscilloscope
becomes the specified value.
(When the  AMS  knob is rotated, the 
 of “EFB= 
” changes
and the waveform changes.) In this adjustment, waveform var-
ies at intervals of approx. 2%. Adjust the waveform so that the
specified value is satisfied as much as possible.
(Read power traverse adjustment)
(Traverse Waveform)
7. Press the  YES  button and save the result of adjustment to the
non-volatile memory (“EFB = 
 SAVE” will be displayed for a
moment. Then “EFB = 
 MO-W” will be displayed).
8. Rotate the  AMS  knob so that the waveform of the oscilloscope
becomes the specified value.
(When the  AMS  knob is rotated, the 
 of “EFB- 
 MO-W”
changes and the waveform changes.) In this adjustment, wave-
form varies at intervals of approx. 2%. Adjust the waveform so
that the specified value is satisfied as much as possible.
(Write power traverse adjustment)
(Traverse Waveform)
9. Press the  YES  button, and save the adjustment results in the
non-volatile memory. (“EFB = 
 SAVE” will be displayed for
a moment.)
10. “EFB = 
 MO-P”. will be displayed.
The optical pick-up moves to the pit area automatically and servo
is imposed.
V : 0.5 V/div
H : 10 ms/div
Input : DC mode
Oscilloscope
BD board
CN105 pin 
4
 (TE)
CN105 pin 
6
 (VC)
VC
A
B
Specification A = B
VC
A
B
Specification A = B
R
5-11. Iop NV SAVE
Write the reference values in the nonvolatile memory to perform
“Iop compare”. As this involves rewriting the reference values, do
not perform this procedure except when adjusting the laser power
during replacement of the OP and when replacing the IC102.
Otherwise the OP check may deteriorate.
Note: Perform this function with the optical pick-up set at room
temperature.
Procedure
1. Rotate the  AMS  knob to display “Iop NV Save” (C06).
2. Press the  YES  button and display “Iop [stop]”.
3. After the display changes to “Iop =xxsave?”, press the  YES
button.
4. After “Complete!” is displayed momentarily, the display changes
to “Iop 7.0 mW”.
5. After the display changes to “Iop=yysave?”, press the  YES
button.
6. When “Complete!” is displayed, it means that Iop NV saving
has been completed.