Barco K5960051-01 User Manual

Page of 256
112    Barco - RHDM-1701 - User manual   
Full functionality description
•  Visible: Setting to define the visibility mode for the UMD bar. 
 
Disabled: the UMD bar is not visible at the bottom of the screen and not visible in OSD. 
 
On screen: UMD is only visible in OSD.
 
Lamps: UMD is visible at the bottom of the screen. 
 
Both: UMD is visible at the bottom of the screen and in OSD.
•  UMD Controlled by: Selects how the UMD bar is controlled:
 
Manual: settings of the UMD bar are defined by the settings in the manual settings sub-
menu.
 
GPI: settings of the UMD bar are defined by the settings in the GPI settings submenu and
controlled by a closed contact GPI. Please consult the addendum for the pinning of the GPI
tally control port. 
•  Manual Settings: Settings to define the UMD bar manually.
•  GPI Settings: Settings that define the control of the UMD bar by the signal at the GPI Tally par-
allel port.
4.3.3.2  Manual settings
•  Brightness: Sets the brightness to the specified value. The possible values are: Full, Half, 1/7,
Dark.
•  Left lamp: Sets the color of the left lamp to the specified value. The possible values are: Red,
Green, Amber, Off
•  Right lamp: Explanation of the setting are the same as for the Left lamp
•  Text: Explanation of the setting are the same as for the Left lamp