7.1.3.4.2
EN norms
•  The unit is targeted to meet following EN specifications: 
•  EN55024 – Susceptibility specifications
Reference
Test Description
Performance Level
Compliant
EN 55022
Conducted Emission
A
YES
EN 55022
Radiated Emission
A
YES
EN 61000-3-2
Conducted Emission Har-
monic Currents
According to Class D
YES
EN 61000-3-3
Voltage Changes Fluctua-
tion
Not applicable
YES
Reference
Test Description
Performance Level
Compliant
EN 61000-4-2 ESD
ESD
4kV contact
8 kV air
Level 3
YES
EN 61000-4-3
Electro Magnetic Field
3 V/m
Level 2
YES
EN 61000-4-4
Burst
0.5 kV Signal ports if ca-
ble > 3m
1 kV on lines & earth
Level 3
YES
EN 61000-4-5
Surges
1.5 kV Signal ports if out-
door
1 kV line to line
2 kV line to earth
Level 3
YES
EN 61000-4-6
Conducted Common Mode 3 V
level 2
YES