MAINTENANCE
CLEANING THE AIR FILTER SCREEN
See Figure 15 - 16.
For proper performance and long life, keep air filter screen 
clean.
  Remove the air filter cover by pushing down on the latch 
with your thumb while gently pulling on the cover.
  Brush the air filter screen lightly to clean. 
  Replace the air filter cover by inserting the tabs on the 
bottom of the cover into the slots on the air filter base; 
push the cover up until it latches securely in place.
CLEANING  THE  EXHAUST  PORT,  MUFFLER 
AND SPARK ARRESTOR
NOTE: Depending on the type of fuel used, the type and 
amount of lubricant used, and/or your operating conditions, the  
exhaust  port,  muffler,  and/or  spark  arrestor  screen  may 
become  blocked  with  carbon  deposits.  If  you  notice  a 
power loss with your gas powered tool, you may need to 
remove these deposits to restore performance. We highly 
recommend that only qualified service technicians perform 
this service.
The  spark  arrestor  must  be  cleaned  or  replaced  every 
50  hours  or  yearly  to  ensure  proper  performance  of  your 
product.  Spark  arrestors  may  be  in  different  locations 
depending on the model purchased. Please contact your 
nearest service dealer for the location of the spark arrestor 
for your model.
WARNING:
To avoid a fire hazard, never run the blower without the 
spark arrestor in place.
VACUUM BAG
A dirty bag will reduce performance. To clean the bag, turn it 
inside out and shake. Wash the bag in soapy water at least 
once a year. To obtain a replacement bag, see 
How to Order 
Replacement Parts on the back page of this manual.
FUEL CAP
 
WARNING:
A leaking fuel cap is a fire hazard and must be replaced 
immediately.
The  fuel  cap  contains  a  non-serviceable  filter  and  a 
check  valve.  A  clogged  fuel  filter  will  cause  poor  engine 
performance. If performance improves when the fuel cap 
is  loosened,  check  valve  may  be  faulty  or  filter  clogged.  
Replace fuel cap if required.
Fig. 15
Fig. 16
SPARK PLUG REPLACEMENT
This  engine  uses  a  Champion  RCJ-6Y  or  NGK  BPMR7A 
spark  plug  with  .05  in.  electrode  gap.  Use  an  exact 
replacement and replace annually.
STORING THE PRODUCT
  Clean all foreign material from the product. Store idle unit 
indoors in a dry, well-ventilated area that is inaccessible 
to children. Keep away from corrosive agents such as 
garden chemicals and de-icing salts.
  Abide by all ISO and local regulations for the safe storage 
and handling of gasoline. 
When storing 1 month or longer:
  Drain  all  fuel  from  tank  into  a  container  approved  for 
gasoline. Run engine until it stops.
Air FilTer
Screen
bruSh
pull coVer 
To open
lATch
Air
FilTer
coVer