Pelco BKMT10/230 Leaflet

Page of 2
REVISION A — 12/93
1
INSTALLATION MANUAL
BKMT10, BKMT10/230, AND BKMT10/24
BLOWER KITS
1.0  SCOPE
The information contained within this manual pertains
to the BKMT10, BKMT10/230, and BKMT10/24
blower kits.
Installation should be in accordance with all applicable
local and national electric codes, utilizing approved
materials only.
2.0  DESCRIPTION
The BKMT10, BKMT10/230, and BKMT10/24 are
continuous duty blower kits designed for use in either
the HT10V or MT10P liquid cooled enclosures.
2.1  MODELS
BKMT10
Blower kit, 6.7 watts @ 120 VAC,
60 Hz, 33 cfm
BKMT10/230
Blower kit, 8.9 watts @ 230 VAC,
50 Hz, 27 cfm
BKMT10/24
Blower kit, 1.92 watts @ 24 VDC
(AC rectified), 30 cfm
®
C468M
Figure 1.  BKMT10 Series Blower Kit Installation
3.0  INSTALLATION
Install the blower kit in either the HT10V or MT10P
enclosure as outlined below.
1.
Remove the rear plate of the enclosure, and
then remove the camera sled.
2.
Assemble blower/blower bracket to sled as
shown in Figure 1, items 1–4.
3.
Install sled into enclosure.
4.
Wire blower to power source using butt
splices provided.
5.
Re-install rear plate of the enclosure.
Item
Description
Part Number
1
1/4-20 bolt
ZH1/420X.750SFS
2
Fan bracket
BK40004001COMP
3
Washer
ZH260X562X65C
4
Nut
ZH1/420NUTCHN
5
Fan Securement
Assembly
Screw
ZH4-40X.500SPP (Qty. 4)
Washer
ZH4LWSIS (Qty. 4)
Nut
ZH4-40NUTSH (Qty. 4)
6
Fans
24 VDC
EH4600105W3
120 VAC
EH4600115W3
230 VAC
EH4600123W3