Chauvet 230SR User Manual

Page of 36
Legend™ 230SR Beam QRG 
EN 
About this 
Guide 
The  Legend™ 230SR Beam  Quick Reference Guide (QRG) has basic 
product information such as connection, mounting, menu options, and 
DMX values. Download the User Manual from 
  for 
more details. 
Disclaimer 
The information and specifications contained in this QRG are subject to 
change without notice. 
Safety Notes
 
· 
DO NOT open this product. It contains no user-serviceable parts. 
· 
DO NOT look at the light source when the product is on. 
· 
CAUTION: This product’s housing is hot when lights are operating.  
· 
CAUTION: This product’s beam is hot when lights are operating. Be 
careful not to aim at fire sprinklers or alarms when in use. 
· 
Mount this product in a location with adequate ventilation, at least 
40 ft (12.2 m) from objects to be lit.  
· 
DO NOT leave any flammable material within 50 cm of this product 
while operating or connected to power. 
· 
USE a safety cable when mounting this product overhead. 
· 
DO NOT operate this product if the housing, lenses, or cables appear 
damaged.  
· 
DO NOT connect this product to a dimmer or rheostat. 
· 
ONLY connect this product to a grounded and protected circuit. 
· 
ONLY use the hanging/mounting bracket or the handles to carry this 
product. Do not carry by the moving head. 
· 
In the event of a serious operating problem, stop using immediately.  
· 
The maximum ambient temperature is 104° F (40° C). Do not operate 
this product at higher temperatures.  
Contact
 
Outside the U.S., United Kingdom, or Ireland, contact your distributor to 
request support or return a product. Visit 
  for 
contact information.
 
What Is 
Included 
· 
Legend™ 230SR Beam 
· 
2-Omega Bracket 
· 
Warranty Card 
· 
Quick Reference Guide 
AC Power 
This product has an auto-ranging power supply that can work with an input 
voltage range of 100~240 VAC, 50/60 Hz. 
AC Plug 
Connection 
Wire (U.S.) 
Wire (Europe) 
Screw Color 
AC Live 
Black 
Brown 
Yellow/Brass 
AC Neutral 
White 
Blue 
Silver 
AC Ground 
Green/Yellow 
Green/Yellow 
Green 
 
Replacing the 
Fuse  
1. 
Disconnect this product from power. 
2. 
Using a Phillips-head screwdriver, unscrew the fuse holder cap from 
the housing. 
3. 
Remove blown fuse and replace with a fuse of the same type and 
rating. 
4. 