Chauvet 6 User Manual
COLORado™ 6 User Manual
17
7/1/2009 4:46 PM
Menu Map
M
AIN
F
UNCTION
S
UB
-F
UNCTION
S
ELECTION
I
NSTRUCTION
Static color
Dimmer
000 ~ 255
(0 ~ 100%)
*Strobe range
is 0 ~ 20
(0 ~ 100%)
*Strobe range
is 0 ~ 20
User can combine Red, Green and Blue to
generate a custom color
Select strobing frequency between 0 and 20 Hz
generate a custom color
Select strobing frequency between 0 and 20 Hz
Red
Green
Blue
Blue
Color Macros
Strobe
Strobe
DMX512
001 ~ 512
Sets the DMX starting address
Personality
Stage 1
12-channel mode
Stage 2
10-channel mode
Pixel
9-channel mode; RGB control for each module
Arc 1
3-channel mode; RGB mode
Arc 1+D
4-channel mode; RGB+D mode
Run Mode
DMX
Allow DMX control
CON
Allow COLOR-CON control
Auto program
1
Choose from 8 Automatic programs
2
3
4
5
6
7
8
Settings
ID address
01 ~ 66
Assigns the ID address to a fixture
ID ON/OFF
On ~ Off
Either enables or disables ID addressing
ADAS faders no
01 ~ 244
Sets the number of ADAS channels for use
when automating DMX channel assignment
when automating DMX channel assignment
ADAS ON/OFF
On ~ Off
Enables the Automatic DMX Addressing
System
System
ADAS copy
On ~ Off
When activated the DMX512 address assigned
by the ADAS will become permanent on the
fixture
by the ADAS will become permanent on the
fixture
Factory settings
Reset confirm Resets fixture to factory default settings
Dimmer start
[001] or [005]
Modify the dimming curve starting value
Password
ON/OFF
On ~ Off
When password is set to on the control panel
will ask for a password each time the control
panel is accessed
will ask for a password each time the control
panel is accessed
Set Password
[
▲▼▲▼▲▲▼▼
]
Use UP and DOWN buttons to set and press
SET to confirm
Note! If you forget the password use the
following factory password:
UP, DOWN, UP, DOWN, UP, UP, DOWN,
DOWN
SET to confirm
Note! If you forget the password use the
following factory password:
UP, DOWN, UP, DOWN, UP, UP, DOWN,
DOWN
Manual Power ON/OFF
The COLORado™ 6 can be turned on and off using the control panel.
P
OWER
A
CTION
Turn OFF
When {MENU} is displayed in the LCD panel, hold down the (EXIT) button for 3
seconds to turn off the fixture.
seconds to turn off the fixture.
Turn ON
Hold the {EXIT} button for 3 seconds to turn power on.