Grizzly h8170 User Manual

Page of 32
H8170/H8171 Hydraulic/Electric Log Splitter
-15-
if the oil level is at least halfway between 
the two grooves, no additional oil is needed 
–wipe  the  dipstick  clean,  return  the  plug, 
and tighten it.
—if  the  oil  level  is  close  to  the  lower  mark, 
add fluid through the oil plug hole until the 
level is at the top line, then tighten the fill 
plug.
Changing the 
Hydraulic fluid 
Always wear protective 
gloves when changing 
hydraulic fluid.
3.  remove  the  oil  fill  plug.  As  the  fluid  drains 
into the basin, loosen the bleeder screw two 
full turns.
4.  While holding a clean rag over the fill open-
ing,  tip  the  splitter  upright,  motor  end  up. 
have your assistant hold it steady.
5  pour new oil into the fill plug hole. Check the 
fluid  level  frequently  as  you  add  oil.  Fill  to 
until the oil level is between the two grooves 
on the dipstick, then replace the fill plug and 
tighten.
 Note: 
Remember to fully tighten the fill plug 
before removing it to check the fluid level. If 
you do not, you run the risk of over-filling, 
which can result in machine damage.
Always wear safety gog-
gles when the changing 
hydraulic fluid.
figure 11. draining hydraulic fluid.
Change  the  hydraulic  fluid  after  each  150  hours 
of  operation.  see  the 
Machine Data Sheet  for 
fluid  requirements  and  capacities  of  your  model. 
Failure to follow tthese instructions may damage 
your machine and cause serious personal injury.
To change the hydraulic fluid:
1.  disConneCt  the  splitter  FroM  the 
poWer sourCe! 
2.  With the help of an assistant, tip the splitter 
back,  motor  end  down,  and  place  a  basin 
under the fill plug to catch the oil as shown in 
figure 11.