14.11
14.11
14.11
14.11  Idle Immediate (E1h/95h) 
Idle Immediate (E1h/95h) 
Idle Immediate (E1h/95h) 
Idle Immediate (E1h/95h)      
Command Block Output Registers 
   Command Block Input Registers 
Register 
7  6  5  4  3  2  1  0     Register 
7  6  5  4  3  2  1  0 
Data 
-  -  -  -  -  -  -  -     Data 
-  -  -  -  -  -  -  - 
Feature 
-  -  -  -  -  -  -  -     Error 
...See Below... 
Sector Count 
-  -  -  -  -  -  -  -     Sector Count 
-  -  -  -  -  -  -  - 
LBA Low 
-  -  -  -  -  -  -  -     LBA Low 
-  -  -  -  -  -  -  - 
LBA Mid 
-  -  -  -  -  -  -  -     LBA Mid 
-  -  -  -  -  -  -  - 
LBA High 
-  -  -  -  -  -  -  -     LBA High 
-  -  -  -  -  -  -  - 
Device 
-  -  -  -  -  -  -  -     Device 
-  -  -  -  -  -  -  - 
Command 
1  1  1  0  0  0  0  1     Status 
...See Below... 
 
Unload Feature 
Command Block Output Registers 
   Command Block Input Registers 
Register 
7  6  5  4  3  2  1  0     Register 
7  6  5  4  3  2  1  0 
Data 
-  -  -  -  -  -  -  -     Data 
-  -  -  -  -  -  -  - 
Feature 
0  1  0  0  0  1  0  0     Error 
...See Below... 
Sector Count 
0  0  0  0  0  0  0  0     Sector Count 
-  -  -  -  -  -  -  - 
LBA Low 
0  1  0  0  1  1  0  0     LBA Low 
1  1  0  0  0  1  0  0 
LBA Mid 
0  1  0  0  1  1  1  0     LBA Mid 
-  -  -  -  -  -  -  - 
LBA High 
0  1  0  1  0  1  0  1     LBA High 
-  -  -  -  -  -  -  - 
Device 
-  -  -  D  -  -  -  -     Device 
-  -  -  -  -  -  -  - 
Command 
1  1  1  0  0  0  0  1     Status 
...See Below... 
 
 
Error Register 
  
Status Register 
  
CRC  UNC 
IDN 
ABT  T0N  AM
   BSY  RDY 
DF 
DSC  DRQ  COR  IDX  ERR 
  
Table 66 Idle Immediate Command (E1h/95h)   
The Idle Immediate command causes the device to enter performance Idle mode.   
The device is spun up to operating speed. If the device is already spinning, the spin up sequence is 
not executed.   
During Idle mode the device is spinning and ready to respond to host commands immediately.   
The Idle Immediate command will not affect the auto power down timeout parameter.   
 
Unload Feature: 
The UNLOAD FEATURE of the IDLE IMMEDIATE command allows the host to immediately unload the heads. 
The device stops read look-ahead if it is in process.    If the device is performing a write operation, the device 
suspends writing cached data onto the media as soon as possible.    The data in the write cache is retained, and the 
device resumes writing the cached data onto the media after receiving a Software Reset, a Hardware Reset, or any 
new command except IDLE IMMEDIATE with UNLOAD FEATURE.