General Information
Hydraulic Hoses 
Hydraulic hoses are subject to extreme conditions such 
as, pressure differentials during operation and exposure 
to weather, sun, chemicals, very warm storage condi­
tions or mishandling during operation or maintenance. 
These conditions can cause damage or premature de­
terioration. Some hoses, such as reel motor hoses, are 
more susceptible to these conditions than others. In­
spect the hoses frequently for signs of deterioration or 
damage. 
When replacing a hydraulic hose, be sure that the hose 
is straight (not twisted) before tightening the fittings. This 
can be done by observing the imprint on the hose. Use 
two wrenches; one to hold the hose straight and one to 
tighten the hose swivel nut onto the fitting. 
Hydraulic Fitting Installation 
O-Ring Face Seal (Fig. 2, 3) 
1. Make sure both threads and sealing surfaces are free 
of burrs, nicks, scratches, or any foreign material. 
2. Make sure the O-ring is installed and properly seated 
in the groove. It is recommended that the O-ring be 
replaced any time the connection is opened. 
3. Lubricate the O-ring with a light coating of oil. 
4. Put the tube and nut squarely into position on the face 
seal end of the fitting and tighten the nut until finger tight. 
5. Mark the nut and fitting body. Hold the body with a 
wrench. Use another wrench to tighten the nut to the 
correct flats from finger tight (F.F.F.T.). The markings on 
the nut and fitting body will verify that the connection has 
been tightened. 
Size 
F.F.F.T. 
4 (1/4 in. nominal hose or tubing) 
.75 
±
 .25 
6 (3/8 in.) 
.75 
±
 .25 
8 (1/2 in.) 
.75 
±
 .25 
10 (5/8 in.) 
1.00 
±
 .25 
12 (3/4 in.) 
.75 
±
 .25 
16 (1 in.) 
.75 
±
 .25 
Before disconnecting or performing any work 
on the hydraulic system, all pressure in the 
system must be relieved by stopping the en­
gine and opening the bypass valve. 
Keep body and hands away from pin hole 
leaks or nozzles that eject hydraulic fluid un­
der high pressure. Use paper or cardboard, 
not hands, to search for leaks. Hydraulic fluid 
escaping under pressure can have sufficient 
force to penetrate the skin and do serious 
damage. If fluid is injected into the skin, it 
must be surgically removed within a few 
hours by a doctor familiar with this type of 
injury or gangrene may result. 
CAUTION 
Nut 
Body 
Sleeve 
Seal 
Figure 2 
Final 
Initial 
Mark Nut 
Position 
Position 
and Body 
Extend Line 
Finger 
Tight 
After 
Proper 
Tightening 
Figure 3 
HydroJect
™ 
3000 
Page 4 - 3 
General Information