Special Tools 
The following special tools are required for servicing the 
Order special tools from the 
TORO SPECIAL TOOLS 
HydroJect 3000. 
A ND  A PP LI CAT IONS   GUIDE   (COMME RCI AL  
PRODUCTS). 
Accumulator Charging Valve and Pressure Gauge  - TOR4001 (Fig. 2) 
The charging valve connects the accumulator to a high 
pressure (3000-3500 or 6000 PSIG) Nitrogen tank for 
pre-charging the accumulator. The charging valve can 
also be used to measure accumulator pre-charge pres­
sure without significant loss of accumulator pre-charge. 
NOTE: The charging tool is equipped with a Com­
pressed Gas Association No. 677 tank connection. 
Figure 2 
1. Accumulator connector 
4. Inlet valve 
2. Pressure gauge 
5. Relief valve 
3. Outlet valve with diffuser 
6. Nitrogen tank connector 
Accumulator Seal Installation Tool - TOR4002 (Fig. 3) 
Used for installing piston seal during accumulator 
rebuilding. 
Figure 3 
Special Tools 
Page 6 - 4 
HydroJect
 3000