Troubleshooting 
The cause of an improperly functioning water system is 
best diagnosed with the use of proper testing equipment 
and a thorough understanding of the complete  system. 
The charts that follow contain detailed information to 
assist in troubleshooting. There may possibly be more 
than one cause for a machine malfunction. 
ALL POSSIBLE CAUSES SHOULD BE CHECKED IN 
THE ORDER IN WHICH THEY ARE LISTED ON THE 
CHARTS. 
Troubleshooting Water System Problems 
Refer to the Testing section of this Chapter for precau­
tions and specific test procedures. 
NOTE: The water aeration system operates under very 
high pressures and severe duty cycles. Performance of 
the water system will be gradually reduced over a period 
of time due to normal wear in the pump, valve and 
accumulator. If you perform water system tests to isolate 
a possible problem, such as reduced hole depth, it is 
recommended that ALL tests be performed in the order 
listed even if the apparent problem has been isolated, 
such as low accumulator pre-charge pressure. This will 
verify that all components are operating properly. 
Condition 
Possible Cause 
Correction 
Machine does not start aerating 
Transport wheels not fully raised 
Check to make sure transport 
when engage button is pushed in 
(unit lowered to aerate mode). 
wheel arms are fully raised (unit 
(pump belt does NOT rotate). 
in aerate mode). 
Low inlet water pressure. 
Check that water pressure gauge 
reads 20 to 30 PSI or more. If 
pressure is low, obtain proper 
water supply source. 
Sheared pump clutch key. 
Repair. 
Electrical problem. 
See Troubleshooting in 
Chapter 5 - Electrical System 
Machine does not start aerating 
Electric brake clutch (valve clutch) 
Check air gap at electric brake
when engage button is pushed in
out of adjustment. 
clutch and adjust if necessary.
(pump belt IS rotating but gear­
case drive shaft is NOT rotating.).
Sheared valve clutch key. 
Repair. 
Electrical problem. 
See Troubleshooting in 
Chapter 5 - Electrical System 
Machine makes unusual noise 
Air in system. NOTE: Relief valve 
With engine OFF and water supp­
when first starting aeration. 
may “squeal” for a short period of 
ly connected, open high pressure 
time during initial startup due to air 
bleed valve and bleed air out of 
in the system. 
system. Repeat procedure if 
noise continues. 
Damaged component. 
Check for damaged components 
and repair or replace as neces­
sary. 
HydroJect
 3000 
Page 6 - 9 
Troubleshooting