Testing
Before Performing Water System Tests 
1. The water aeration system operates under very high 
pressures and severe duty cycles. Performance of the 
water system will be gradually reduced over a period of 
time due to normal wear in the pump, valve and ac­
cumulator. If you perform water system tests to isolate 
a possible problem, such as reduced hole depth, it is 
recommended that ALL tests be performed in the order 
listed even if the apparent problem has been isolated, 
such as low accumulator pre-charge pressure. This will 
verify that all components are operating properly. 
j
High pressure water system components can 
cause personal in ury if disassembled incor­
rectly. Discharge water pressure at bleed 
valve before attempting any water system 
servicing. Open bleed valve slowly and avoid 
contact with high velocity water stream. 
WARNING 
2. With engine OFF, open high pressure bleed valve, 
and inspect aeration nozzles. Check for plugged noz­
zles. Verify size and quantity (see Nozzle Service and 
Replacement). Nozzles that are too large will cause loss 
in pressure and could cause damage to the accumulator 
and other water system components. 
NOTE: You can check for plugged nozzles by aerating 
over a piece of cardboard, then inspecting cardboard. 