Toro 11185SL User Manual

Page of 315
Reelmaster 7000
Page 5 -- 37
Electrical System
Fuel Pump
The fuel pump is energized by the TEC controller when
the ignition switch is either in the START or ON position.
The fuel pump is attached to the left side frame rail.
IMPORTANT: When testing fuel pump, make sure
that pump is not operated without fuel.
Fuel Pump Capacity Test
1. Park machine on a level surface, lower cutting units,
stop engine and engage parking brake. Remove key
from ignition switch.
2. Raise and support hood.
3. Remove 20A fuse (F1--1) (Fig. 54) from fuse block to
prevent the engine from cranking.
4. Make sure fuel hoses attached to the fuel pump are
free of obstructions.
5. Disconnect fuel pump discharge hose from the fuel/
water separator inlet fitting (Fig. 53).
6. Place disconnected fuel hose (pump discharge) into
a large, graduated cylinder sufficient enough to collect
1 quart (0.95 liter).
7. Collect fuel in the graduated cylinder by turning igni-
tion switch to the ON position. Allow pump to run for fif-
teen (15) seconds, then turn switch to OFF.
8. The amount of fuel collected in the graduated cylin-
der should be approximately 16 fl oz (475 ml) after fif-
teen (15) seconds.
9. Replace fuel pump if necessary.
10.Install fuel hose to the fuel/water separator. Secure
hose with hose clamp.
11.Install 20A fuse into fuse block.
12.Bleed the fuel system.
13.Lower and secure hood.
1. Fuel/water separator
2. Pump discharge hose
3. Inlet fitting
Figure 53
2
1
3
Figure 54
FRONT
F3
F2
F1
2A
7.5A
7.5A
7.5A
10A
10A
10A
10A
20A
OP
TION
OP
TION
OP
TION
M1 (60A)
M2 (option)
Fuel Pump Specifications
Pump Capacity
64 fl oz/min (1.9 l/min)
Pressure
7 PSI (48.3 kPa)
Current Draw
2.0 amp
Electrical System