Toro 4100-D User Manual

Page of 298
Groundsmaster 4100--D
Hydraulic System
Page 4 -- 2
Specifications
Item
Description
Piston (Traction) Pump
Eaton Variable Displacement Piston Pump
(Model 72400)
System Relief Pressure: Forward
4000 PSI (274 bar)
System Relief Pressure: Reverse
5000 PSI (343 bar)
Charge Pressure
250 PSI (17 bar)
Front Wheel Motors
Eaton Fixed Displacement Piston Motors
(Model 74328)
Rear Axle Motor
Eaton Fixed Displacement Piston Motor
(Model 74315)
Gear Pump
Casappa 4 section, positive displacement gear type pump
Section P1/P2 Displacement (per revolution)
1.37 Cubic Inches (22.46 cc)
Section P3/P4 Displacement (per revolution)
0.56 Cubic Inches (9.16 cc)
Steering Control Valve
Eaton Steering Unit, Series 5
Steering Relief Pressure
1350 PSI (93 bar)
Lift/Lower Relief Pressure
2525 PSI (174 bar)
Cutting Deck Motors
Sauer Danfoss Gear Motor
Cutting Deck Circuit Relief Pressure
Center and Left Side
3000 PSI (207 bar)
Right Side
2000 PSI (137 bar)
Engine Cooling Fan Motor
Casappa Gear Motor
Displacement (per revolution)
0.50 Cubic Inches (8.3 cc)
Engine Cooling Fan Circuit Relief Pressure
3000 PSI (207 bar)
Hydraulic Filters
Spin--on cartridge type
In--line Suction Strainer
100 mesh (in reservoir)
Hydraulic Reservoir
8 U.S. Gallons (30.3 Liters)
Hydraulic Oil
See Operator’s Manual