Page 141 of 176 
 
14.38
14.38
14.38
14.38  Set Multiple (C6h) 
Set Multiple (C6h) 
Set Multiple (C6h) 
Set Multiple (C6h)      
Command Block Output Registers 
   Command Block Input Registers 
Register 
7  6  5  4  3  2  1  0     Register 
7  6  5  4  3  2  1  0 
Data 
-  -  -  -  -  -  -  -     Data 
-  -  -  -  -  -  -  - 
Feature 
-  -  -  -  -  -  -  -     Error 
...See Below... 
Sector Count 
V  V  V  V  V  V  V  V     Sector Count 
-  -  -  -  -  -  -  - 
LBA Low 
-  -  -  -  -  -  -  -     LBA Low 
-  -  -  -  -  -  -  - 
LBA Mid 
-  -  -  -  -  -  -  -     LBA Mid 
-  -  -  -  -  -  -  - 
LBA High 
-  -  -  -  -  -  -  -     LBA High 
-  -  -  -  -  -  -  - 
Device 
-  -  -  -  -  -  -  -     Device 
-  -  -  -  -  -  -  - 
Command 
1  1  0  0  0  1  1  0     Status 
...See Below... 
 
Error Register 
  
Status Register 
  
CRC  UNC 
IDN 
ABT  T0N  AM
   BSY  RDY 
DF 
DSC  DRQ  COR  IDX  ERR 
  
Table 108 Set Multiple Command (C6h)   
The Set  Multiple command enables  the device to perform Read and Write Multiple commands and 
establishes  the  block  size  for  these  commands.  The  block  size  is  the  number  of  sectors  to  be 
transferred for each interrupt.   
The  default  block  size  after  power  up  is  0,  and  Read  Multiple  and  Write  Multiple  commands  are 
disabled.   
If an invalid  block  size is specified, an Abort error will be returned to  the host, and  Read Multiple 
and Write Multiple commands will be disabled.   
Output Parameters To The Device 
Sector Count 
The block size to be used for Read Multiple and Write Multiple commands. Valid 
block sizes can be selected from 0, 1, 2, 4, 8 or 16. If 0 is specified, then Read Multiple 
and Write Multiple commands are disabled.