7K500 OEM Specification 
Page 70 of 176 
13  
13  
13  
13   Command Protocol 
Command Protocol 
Command Protocol 
Command Protocol      
The  commands  are  grouped  into  different  classes  according  to  the  protocols  followed  for  command 
execution. The command classes with their associated protocols are defined below.   
Please  refer  to  Serial  ATA  Revision  2.6  (Section  11.  device  command  layer  protocol)  about  each 
protocol. 
For  all  commands,  the  host  must  first  check  if  BSY=1,  and  should  proceed  no  further  unless  and 
until BSY=0. For all commands, the host must also wait for RDY=1 before proceeding.   
A device must maintain either BSY=1 or DRQ=1 at all times until the command is completed. The 
INTRQ signal is used by the device to signal most, but not all, times when the BSY bit is changed 
from 1 to 0 during command execution.   
A command shall only be interrupted with a COMRESET or software reset. The result of writing to 
the Command register while BSY=1 or DRQ=1 is unpredictable and may result in data corruption. A 
command  should  only  be  interrupted  by  a  reset  at  times  when  the  host  thinks  there  may  be  a 
problem, such as a device that is no longer responding.   
Interrupts  are  cleared  when  the  host  reads  the  Status  Register,  issues  a  reset,  or  writes  to  the 
Command Register.   
“Table 139 Timeout Values” on Page 174 shows the device timeout values.   
 
13.1
13.1
13.1
13.1  Data In Commands 
Data In Commands 
Data In Commands 
Data In Commands      
These commands are:   
  Device Configuration Identify   
  Identify Device   
  Read Buffer   
  Read Log Ext   
  Read Multiple   
  Read Multiple Ext   
  Read Sector(s)   
  Read Sector(s) Ext   
  S.M.A.R.T. Read Attribute Values   
  S.M.A.R.T. Read Attribute Thresholds   
  S.M.A.R.T. Read log sector   
Execution includes  the transfer of one or more 512 byte (>512 bytes on Read Long) sectors of data 
from the device to the host.   
Note that the status data for a sector of data is available in the Status Register before
before
before
before the sector is 
transferred to the host.   
If the device detects an invalid parameter, then it will abort the command by setting BSY=0, ERR=1, 
ABT=1.   
If  an  error  occurs,  the  device  will  set  BSY=0,  ERR=1,  and  DRQ=1.  The  device  will  then  store  the 
error status in the Error Register. The registers will contain the location of the sector in error. The 
erroneous location will be reported with CHS mode or LBA mode, the mode is decided by mode select 
bit (bit 6) of Device register on issuing the command.   
 
13.2
13.2
13.2
13.2  Data Out Commands 
Data Out Commands 
Data Out Commands 
Data Out Commands      
These commands are:   
  Device Configuration Set   
  Download Microcode 
  Format Track   
  Security Disable Password   
  Security Erase Unit