HGST Travelstar 7K500 BE, 320GB 0A79103 User Manual

Product codes
0A79103
Page of 176
7K500 OEM Specification 
Page 88 of 176 
 
14.8
14.8
14.8
14.8  Format Unit (F7h: V
Format Unit (F7h: V
Format Unit (F7h: V
Format Unit (F7h: Vendor Specific) 
endor Specific) 
endor Specific) 
endor Specific)      
Command Block Output Registers 
   Command Block Input Registers 
Register 
7  6  5  4  3  2  1  0     Register 
7  6  5  4  3  2  1  0 
Data 
-  -  -  -  -  -  -  -     Data 
-  -  -  -  -  -  -  - 
Feature 
V  V  V  V  V  V  V  V     Error 
...See Below... 
Sector Count 
-  -  -  -  -  -  -  -     Sector Count 
-  -  -  -  -  -  -  - 
LBA Low 
-  -  -  -  -  -  -  -     LBA Low 
-  -  -  -  -  -  -  - 
LBA Mid 
-  -  -  -  -  -  -  -     LBA Mid 
-  -  -  -  -  -  -  - 
LBA High 
-  -  -  -  -  -  -  -     LBA High 
-  -  -  -  -  -  -  - 
Device 
-  -  -  -  -  -  -  -     Device 
-  -  -  -  -  -  -  - 
Command 
1  1  1  1  0  1  1  1     Status 
...See Below... 
 
Error Register 
  
Status Register 
10 
  
CRC  UNC 
IDN 
ABT  T0N  AM
   BSY  RDY 
DF 
DSC  DRQ  COR  IDX  ERR 
  
Table 53 Format Unit Command (F7h)   
The Format Unit command initializes all user data sectors after merging reassigned sector location 
into  the  defect  information  of  the  device  and  clearing  the  reassign  information.  Both  new  reassign 
information and new defect information are available right after this command completion, and are 
also  used  on  next  power  on  reset.  Both  previous  information  are  erased  from  the  device  by  this 
command.   
Note that the Format Unit command initializes from LBA 0 to Native MAX LBA. Host MAX LBA set 
by Initialize Drive Parameter or Set MAX ADDRESS command is ignored. So the protected area by 
Set MAX ADDRESS commands is also initialized.   
The  security  erase  prepare  command  should  be  completed  immediately  prior  to  the  Format  Unit 
command.  If  the  device  receives  a  Format  Unit  command  without  a  prior  Security  Erase  Prepare 
command the device aborts the Format Unit command.   
If Feature register is NOT 11h, the device returns Abort error to the host.   
This command does not request to data transfer.   
Output Parameters To The Device 
Feature 
Destination code for this command 
  
11H Merge reassigned location into the defect information 
The execution time of this command is shown below.   
HTS725050A9A3XX 
128 min 
HTS725040A9A3XX 
106 min 
HTS725032A9A3XX 
83 min 
HTS725025A9A3XX 
65 min 
HTS725016A9A3XX 
50 min 
HTS725012A9A3XX 
31 min