Holder C 9.72 H User Manual

Page of 221
Operating Instructions
145 052
109
C 9700 ... C 9.88 H
Operating the Implements
ATTENTION
Increase the engine speed, but then increase
the oil flow only slowly.
-
Turn the rotary knob (5) to adjust the oil flow from 0 to
100 litres/min until the desired flow rate for the imple-
ment is reached.
The figure on the ring x10 corresponds roughly to the
oil flow in litres per minutes at full throttle.
NOTE
With the setscrew at the stop ring (6) it is
possible to set a stop so that a certain flow
rate for an implement is not exceeded.
ATTENTION
If the implement is no longer used, turn the
variable pump for implements off with the
star ting safety switch to prevent any
unnecessary overheating of the hydraulic oil.
Turning Off the Variable Pump for Implements
-
Turn off the starting safety switch (7). The indicator in
the switch extinguishes.
Bild_093
5
6
7
NOTE: If the variable pump for the implements is not first
switched off when you:
turn off the engine,
set the drive program switch to 0,
started with the forward/reverse selector lever in the
forward or reverse position
you can not, for safety reasons, immediately restart the
variable pump for implements.
Before a renewed start you must either first:
-
set the rotary knob to 0, or
-
turn the starting safety switch off and on again once, or
-
operate the forward/reverse selector lever once through
neutral.