3M 2273ME User Manual

Page of 52
78-8130-6151-8-E 
27
7.  Continue along the cable/pipe path, re-inserting the frame probes every few steps 
while watching the receiver bar graphs. The bar graph on the receiver will fill 
toward the right side of the screen (green), indicating that the fault is ahead of 
the operator (in the direction of the green-banded leg of the 3M
 Dynatel
 Earth 
Contact Frame).
Transmitter Signal
Green Band
Red-and-White-Striped Band
8.  When the bar graph fills toward the left (red-and-white-striped) side of the screen, 
the fault has been passed and is now behind the operator. Move back, inserting the 
frame every few inches, until the arrows alternate back to green. Mark the point 
beneath the center of the frame. Turn the earth frame 90 degrees and insert into the 
ground over the previously marked point. Move the earth frame to the left and right 
(following the directions of the green and red arrows). When the arrows reverse a 
third time, turn the frame 90 degrees again. Pinpoint the fault by moving the frame 
in the direction of the green and red arrows. The fault is located beneath the center 
of the frame when the arrows change from one side to the other this time.
Figure 2
9.  To verify the fault location, insert the frame’s red-and-white-striped probe directly 
on the spot identified above. Pivot the frame in a circle around the red-and-white-
striped leg re-inserting the green-banded leg in the ground every few degrees of the 
circle (Figure 2). The arrow should always point toward the left (red) indicating that 
the fault is directly below the red-and-white-striped leg.
10.  After a fault is found and pinpointed, move the earth contact frame about one frame 
width away from the fault and insert it in the ground with the green-banded leg 
towards the fault. Compare the numeric signal level with the fault level reference 
indicated in the lower left box labeled REF. If the reading is within 12 dB of the 
reference, the operator has found the major fault. If the fault reading does not fall 
within 12 db of the reference reading, multiple faults may exist. The signal level 
of this secondary fault can be saved by pressing Fault 1 [SK] or Fault 2 [SK]. The 
fault with the highest reading will be the primary fault.