3M 2273ME User Manual

Page of 52
78-8130-6151-8-E 
31
5.  Adjust the Gain Down [4] until the bar graphs open.
 
− The bar graph will close, the audio will increase, and the signal strength will be 
maximum when the receiver detects a marker of the specified utility.
 
− When one of the two markers is detected, press the “XXX Only” [SK] for the 
detected utility marker.
 
− The unit will switch to Single Marker Locate in order to pinpoint the marker.
6.  Press Markr 2 [SK Toggle] to return to Dual Marker Locate.
Marker Depth Estimate
ID Marker Depth
1.  Lower the tip of the receiver to the ground over the targeted marker.
2.  Press Depth [SK].
 
− The receiver will examine the marker 
(Calculating, please wait...)
 
− If the marker is a 3M
 Dynatel
 iD 
Marker, the receiver will display the 
depth of the marker, and its identification 
number.
3.  To save the depth reading, press Mem Select 
[SK].
 
− Five depth readings can be saved with the 
time, date, and its identification number.
 
− Save [SK] will place each entry in 
sequential order in memory (M1 - M5) 
until five readings have been stored. The 
unit will overwrite saved entries in excess 
of five, beginning with M1.
4.  Press Clear All [SK] to delete all stored depth information.
5.  Press Mem Select [SK] to select the memory location to store the depth readings. 
When the preferred location appears on the screen, press Save [SK]. The screen and 
memory location will populate with the current information.
6.  Each memory location can be reviewed by pressing Mem Select [SK].
7.  Press Locate [5] to return to Marker Locate Mode.