American Standard 6030Y2A.118.XXX User Manual

Page of 4
7 5 4 2 8 2 - 1 0 0   R e v .   A
- 2 -
INSTALLATION INSTRUCTIONS
STEP 1. PREPARING ALCOVE
•  Alcove studs should be constructed as shown.
•  Floor must be clean, smooth, and level (check with level). Sub floor must be 
installed. Do not install tub on open floor joists.
•  Cut hole in sub floor as shown, to accommodate drain.
•  Access panels must be located on both ends of whirlpool alcove to service 
pump/motor and drain assembly after installation. Failure to provide access 
to these areas may result in added removal and re-installation costs in the 
event service may be required.
STEP 2. ELECTRICAL CONNECTIONS
•  Install a 110 volt, 20 amp duplex outlet to the stud wall underneath the 
whirlpool at least 4" (102mm) above the sub floor. (Figure 1) 
•  Motor/pump must have a separate 110 volt, 20 amp service from the breaker 
panel to the motor/pump location. Do not combine any other electirc service 
with whirlpool supply line.
•  Service supply line must be connected to a ground fault interrupter (GFI) at 
the breaker panel for added protection and to meet code requirement. Install 
breaker after all other electrical connections have been made.
•  Your whirlpool wiring should be installed by a licensed electrician. All 
electrical preparation and connections must be made in strict compliance 
with local and national electrical codes.
    WARNING: If whirlpool is not properly wired, there                                       
 
          is danger of electrical shock or fire.
STEP 3. LEAK TEST WHIRLPOOL
•  Water test tub in area where all fittings and connections can be 
inspected.
•  Fill tub with water, make sure water is above jets. Run for 10 minutes. 
Inspect all fittings, plugs and connections for possible leaks.
•  Drain tub. If any leaks are found, call American Standard Customer Service 
Department at 1-800-442-1902.
STEP 4. INSTALLING WHIRLPOOL
•  Install drain, waste and overflow.
•  Trial fit whirlpool in prepared alcove. With whirlpool sitting flat on floor, check 
with level on top of tub. Whirlpool should be level from front to back and side 
to side (Figure 2). If tub is not level, remove tub and level floor using leveling 
compound.
•  A floor leveling compound (smooth mortar) or a similar quick-setting 
compound specifically made for leveling floors may be used to fully support 
and level tub.
•   If alcove is larger than tub, shim between tub and studs to create a tight fit. 
Screw tub flange to studs. (Figure 3)
•  Connect drain piping to drain.
FIGURE 2. Check to assure tub is level.
FIGURE 1. Locate receptacle in same end of alcove 
as motor.
FIGURE 3. If necessary, shim between tub and 
studs for tight fit and screw to each stud.
4"
102mm
Wire to ground 
fault interrupter