Invacare 3800 User Manual
SECTION 2—PARTS AND INSTALLATION
19
6. Open the service access panel to access pump electric connections (Detail “A”).
7. Route electrical line through electrical line routing hole. Refer to Electrical and
7. Route electrical line through electrical line routing hole. Refer to Electrical and
Plumbing Hook‐up Locations on the Tub on page 17 for the location of this hole.
8. Remove the motor cover (Detail “C”).
9. Connect ground, neutral and hot wires from wall directly to motor (Detail “D”).
9. Connect ground, neutral and hot wires from wall directly to motor (Detail “D”).
FIGURE 2.6 Electrical Installation
Service Access Panel
Wall
Tub Wall
Pump
Motor
BLACK
WHITE
GREEN
DETAIL “A” - ACCESS PANEL
DETAIL “B” - ELECTRICAL SCHEMATIC
Air Switch Line
Motor
Cover
Cover
Ground (GREEN)
Line (BLACK)
Neutral (WHITE)
Ground
Line
Neutral
DETAIL “D” - MOTOR END PLATE
DETAIL “C” - MOTOR COVER
115 V Electrical Hook-up