Invacare 3800 User Manual

Page of 36
SECTION 2—PARTS AND INSTALLATION
19
6. Open the service access panel to access pump electric connections (Detail “A”).
7. Route electrical line through electrical line routing hole. Refer to Electrical and 
8. Remove the motor cover (Detail “C”).
9. Connect ground, neutral and hot wires from wall directly to motor (Detail “D”).
FIGURE 2.6   Electrical Installation
Service Access Panel
Wall
Tub Wall
 Pump 
Motor
BLACK
WHITE
GREEN
DETAIL “A” - ACCESS PANEL
DETAIL “B” - ELECTRICAL SCHEMATIC
Air Switch Line
Motor 
Cover
Ground (GREEN)
Line (BLACK)
Neutral (WHITE)
Ground
Line
Neutral
DETAIL “D” - MOTOR END PLATE
DETAIL “C” - MOTOR COVER
115 V Electrical Hook-up