SECTION 5—TROUBLESHOOTING
35
SECTION 5—TROUBLESHOOTING
NOTE: If problems are not remedied by the suggested means above, contact an ICCG dealer or 
technical support.
SYSTEM/OPERATION
SYMPTOMS
FAULTS
SOLUTION
Hydromassage System
System will not start
No electrical power to tub Check and reset breaker or 
GFCI.
System not prepared
Be sure water level is above jets.
Check that inlet plug on tub is 
depressed.
Switch hose disconnected
Reconnect hose to switch and 
motor.
System is ineffective
Water deposits in 
whirlpool jets
Disassemble and clean whirlpool 
jets.
Whirlpool jets closed
Open whirlpool jets.
Aerator closed
Open aerator.
Whirlpool intake clogged
Inspect intake and remove 
obstruction.
Disinfecting System
No discharge from 
disinfectant wand
Whirlpool jets open
Close whirlpool jets.
Whirlpool intake open
Close whirlpool intake.
Hose kinked
Inspect hose and unkink.
Disinfectant siphon tube 
kinked
Inspect siphon tube and unkink.
Flow meter adjustment 
knob turned off
Turn flow meter adjustment knob 
to proper setting.
Tub Operation
No water flow
Water supply turned off
Turn on water supply.
Restricted water flow RADA valve. Refer to 
RADA owner’s manual.
Inspect and clean RADA valve.