Toro 4042 User Manual

Page of 188
Greensmaster eFlex 1800/2100
Traction and Reel Drive System
Page 3 -- 11
Service and Repairs
Reel Drive Belt
EFlex machines use a positive drive belt on the left side
of the machine to operate the cutting unit.
Removal
1. Park machine on level surface. Turn key switch to the
OFF position and remove key from the switch. Discon-
nect the battery pack (see Battery Pack Connection in
the General Information section of this chapter).
2. Remove reel drive cover to expose reel drive belt
(Fig. 14).
3. Loosen the bearing housing mounting nut (Fig. 15).
4. Using a 5/8” (16mm) wrench, rotate the bearing
housing to release tension on reel drive belt (Fig. 15).
5. Remove reel drive belt from the pulleys.
Installation
1. Make sure that the battery pack is disconnected (see
Battery Pack Connection in the General Information
section of this chapter).
2. Using a 5/8” (16mm) wrench, rotate and hold the
bearing housing to allow reel drive belt installation (Fig.
15).
3. Place a new drive belt onto the pulleys.
4. Release bearing housing to apply tension to reel
drive belt. Make sure that bearing housing rotates freely
which will allow accurate belt tension.
5. Rotate reel drive at least one (1) full turn to ensure
that drive belt is properly tensioned.
6. Tighten the bearing housing mounting nut (Fig. 15).
7. Install reel drive cover to machine and secure with
flange head screw (Fig. 14).
8. Connect the battery pack (see Battery Pack Connec-
tion in the General Information section of this chapter).
1. Reel drive cover
2. Flange head screw
Figure 14
1
2
1. Reel drive belt
2. Bearing housing nut
3. Compression spring
4. Bearing housing
Figure 15
1
2
3
4
Tra
ction
and
Ree
l
Dri
ve
Sys
te
m