DeWALT A16505 User Manual

Page of 64
1
E
n
g
li
sh
•  NEvER turn water supply off while pressure washer engine is 
running or damage to pump will result.
•  DO NOT stop spraying water for more than two
T
 
minutes at a time. Pump operates in bypass 
mode when spray gun trigger is not pressed. 
When  the  temperature  inside  the  pump  rises 
too  high  the  thermal  relief  valve  (T)  will  open 
and release a gush of water in an effort to lower 
the temperature inside the pump. The thermal 
relief valve will then close. If pump is left in bypass mode for 
more than two minutes internal components of the pump can 
be damaged.
start-uP ProceDure 
  1. In a well-ventilated outdoor area, add fresh, high-quality, unleaded 
gasoline with a pump octane rating of 86 or higher. Do not overfill. 
Wipe  up  spilled  fuel  before  starting  the  engine.  Refer  to  engine 
instruction manual for correct procedure.
  . Check  engine  oil  level.  Refer  to  the  engine  instruction  manual  for 
correct procedure. 
  3. Connect the water hose to the water source. Turn the water source 
on to remove all air from the hose. When a steady stream of water 
is present, turn the water source off.
  4. Verify  the  filter  screen  (U)  is  in  water  inlet  of
U
 
pump. The cone side faces out.
  5. Connect  the  cold  water  source  (V)  to  pump 
inlet. 
   
note: Water source must provide a minimum 
of 5 gallons per minute at 0 PSI. 
WARNING:  To  reduce  the  possibility  of  con-
tamination  always  protect  against  backflow  when  connected  to  a 
potable water system.
  6. Connect  high-pressure  hose  (C)  to  pump 
V
C
outlet.
  7. If applying a chemical or cleaning solution, 
refer  to 
chemicals  and  cleaning 
solvents.
  8. Turn the water source on. 
cAutIoN:  Risk  of  property  damage.  Failure 
to do so could cause damage to the pump.
  9. Remove all air from the pump and high pressure hose by depress-
ing trigger until a steady stream of water is present.
 10. Start  engine.  Refer  to  the  engine  instruction  manual  for  correct 
procedure. 
WARNING:  Risk  of  unsafe  operation.  If  engine  does  not  start 
after two pulls, squeeze trigger of gun to relieve pump pressure. Pull 
starter cord slowly until resistance is felt. Then pull cord rapidly to 
avoid kickback and prevent hand or arm injury. 
 11. Depress trigger on gun to start water flow.
WARNING:  Risk  of  unsafe  operation.  Stand  on  a  stable  
surface and grip gun/wand firmly with both hands. Expect the gun to 
kickback when triggered.
 1. Release trigger to stop water flow.
DANGeR: Risk of injury from spray. Engage the 
trigger lock (W) when gun is not in use to prevent 
accidental spraying.
 13. Adjust  spray  for  the  task  being  performed  by 
changing quick connect nozzle. Refer to 
spray 
Wand nozzles.
Shutting Down
  1. If  chemicals  were  applied,  place  the  chemical  hose  into  a 
container of clean water and draw clean water through chemical 
injection system to rinse system thoroughly.
 
W