Shutdown, Flushing and Storage 
10
309286K
Shutdown, Flushing and Storage
Short-term Storage (less than 30 
days)
Before you store the pressure washer overnight or 
transport it, disconnect the water supply and 
CLOSE the fuel supply valve.
After each use, wipe all pressure washer surfaces 
with a clean, damp cloth.
Long-term (more than 30 
days)/Winter Storage
Do not store unit outside where it can be exposed to 
rain, dirt or adverse weather conditions.
Do not expose pressure washer to freezing temper-
atures or allow water to freeze in pressure washer 
components which could cause the pump to 
lock-up. If this happens, allow the pump to thaw nat-
urally in a WARM ENVIRONMENT. Do not attempt 
to speed up this process by pouring warm water on 
the pump. This could cause additional damage to 
the pump.
ENGINE:
1.
Run engine until gas is gone or stabilize fuel and run 
it through fuel system and carburetor.
2.
Drain water out of pressure washer hose.
3.
Turn fuel system of OFF position.
PUMP:
1.
Place an antifreeze solution approximately 1 foot off 
the ground. Attach one end of a 4- or 5-foot section 
of hose to pump inlet and other end in the antifreeze 
solution.
2.
Pull starter rope on engine until antifreeze comes 
out of pump outlet.
STORAGE LOCATION
Store pressure washer in garage, basement, or in an 
area where it is protected from freezing temperatures.
ti5441a
ti5442a