Cooper Lighting E3AASR Leaflet

Page of 2
C A T A L O G # : 
T Y P E : 
Specification grade, wet listed 71 watt 
MR16 lamp adjustable fixture. 
Adjustment mechanism features hot 
aiming capability, aiming marks and too- 
less locking. Optics provide glare-free 
50° cutoff to lamp and lamp image. For 
use with all halogen MR16 lamp vari- 
eties. Units small size is ideal for tight 
construction areas. Insulation must be 
kept 3" away from sides and top of fix- 
ture. Optical element can be changed 
after installation to provide a variety of 
distributions. e.g. into a Downlight 
 
. . . 
Re f l e c t o r 
.040 thick aluminum spun parabolic interior 
reflector in Clear, Gold, Haze, Warm Haze, Black 
Alzak® finish 
Special cone colors listed below. 
 
. . . 
G l a s s 
.125 thick tempered clear glass protects lamp 
from direct spray of water and is retained during 
relamping. 
 
. . . 
F l a n g e 
Self flange reflector or die-cast flange with either 
matte white or clear coat finishDie-cast flanges 
are easily removed for field painting. Elements are 
keyed for proper insertion. 
 
. . . 
A d j u s t a b i l i t y 
Removable lamp adjustment mechanism provides 
up to 45° tilt and 361° rotation and locks into any 
aiming position. Unit is relamped without unlocking 
adjustments. Translating centerbeam optics maxi- 
mize light output. 
 
. . . 
L e n s 
Soft focus lens standard for smooth beam 
patterns. Up to two filter media can be used 
which are retained during relamping. 
 
. . . 
A t t a c h m e n t 
Positive torsion springs pull flange tight to ceiling. 
Mechanical light trap eliminates spill light at edge 
of flange or reflector. 
 
. . . 
So c k e t 
GX5.3 base for Bi-pin MR16 lamps. Back light 
shield keeps interior of fixture dark. 
 
. . . 
T r a n s f o r m e r 
Truvolt 
™ 
toroidal transformer with dual-output taps 
for proper 12.0V operation and quiet operation 
when dimmed. Dimmer tap compensates for inher- 
ent voltage loss from dimmers, resulting in 30% 
more lumens than traditional laminated transform- 
ers. Toroidal design, with 90% or greater efficien- 
cy, features a rolled one-piece continuous core of 
M3 grade grain oriented silicon steel complete with 
an integral thermal to protect against overheating. 
For dimming, use dimmers rated for electromagnet- 
ic transformers. Transformer is warranted for 5 
years and is serviceable from below ceiling. 
Note: If a dimming system is operated for con- 
struction lighting in its "shunt" mode, i.e. bypass- 
ing the dimmer modules, for an extended period of 
time, fixtures with the dual-tap toroidal transformer 
should be operated on the "Switched Fixture" out- 
put until the dimmers are in use. Operating fixtures 
on the "Dimmed Fixture" output with a full 120v 
input for an extended period will overdrive the 
lamp and cause shortened lamp life. 
 
. . . 
F r a m e / H o u s i n g 
Hot dipped galvanized 20 gauge steel frame 
with built in 1/2 inch plaster lip. Gunsights allow 
for consistent alignment. 
 
. . . 
J u n c t i o n   B o x 
18 cubic inches, listed for 4#12 AWG or 6#14 
AWG 90° C additional feed through conductors, 
has three 1/2" pryouts. 
 
. . . 
B a r   H a n g e r s 
No Flex 
® 
bar hangers with positive locking, for 
use with wood, engineered wood and steel frame 
joists spaced up to 24" O.C. ship with platform. 
For use in T-bar ceilings order accessory push on 
clips. Nailess barb and locator lip provide consis- 
tent installation height. 
 
. . . 
C o d e s 
Thermally protected, IP labeled. Unit is airtight and 
exchanges less than 2.0 CFM with the plenum at a 
pressure of 75 pascals.  Insulation must be kept 
three inches away from fixture sides and none on 
top as to entrap heat. 
 
. . . 
L a b e l s 
                       
 
 
 
 
 
 
 
 
 
 
 
 
 
         
3 "   A D J U S T A B L E 
S H O W E R 
 
 

 
           
3 1/2" 
[89mm] 
4 3/8" 
[112mm] 
5 1/8" 
[130mm] 
5" 
[127mm] 
8 5/8" 
[220mm] 
4 3/8" 
[112mm] 
11 7/8" 
[302mm] 
E N E R G Y   D A T A 
120V Input 
Lamp
Input Operating 
Watts 
Watts
Current 
20
23
.19 
35
41
.34 
37
42
.35 
42
47
.39 
50
57
.48 
65
70
.58 
71
77
.64 
75
81
.68 
Note: O.D. on SF 
is 4 7/8" 
Ceiling Cutout: 
4 3/8" [112mm] 
ADI042551 
                     
S A M P L E   N U M B E R :   P N 3 M R - E 3 A A S R C 
Complete unit consists of a platform and element 
  
 
PN3MR = 3"  Non- 
IC Low Voltage 
Housing 
PN3MR REMOTE = 
3"  Non-IC Housing 
for Remote 
Transformer 
P l a t f o r m 
A c c e s s o r i e s 
MBCLP = 40 
Push On T Bar 
Clips (for 10 
Units) 
PLE3 = Plaster 
Lip Extension 
for Max 2" 
Thick Ceiling 
L-SPD = 
Spread Lens 
L-LNR = Linear 
E3AASR 
= 3" 
MR16 
0 - 45° 
Adjustable 
Accent 
Lensed 
Reflector 
O p t i c a l 
E l e m e n t 
Blank= White 
die-cast 
SF= Self 
Flange 
SFWF= Self 
Flange Painted 
White 
RAW= Natural 
Die Cast 
F l a n g e 
F i n i s h 
Standard 
C=Clear 
H=Haze 
G=Gold 
WMH=Warm 
Haze 
W=Gloss White 
B= Black 
MW= Matte 
White 
Custom 
K=Cognac 
KH=Cognac 
Haze 
CC=Chocolate 
Custom 
CCH=Chocolate 
Haze 
BU=Blush 
Custom Cont. 
BUH=Blush 
Haze 
GP=Graphite 
GPH=Graphite 
Haze 
PN=Pine 
PNH=Pine Haze 
SK=Sky 
SKH=Sky Haze 
Spread Lens 
L-UV = UV 
Reduction Lens 
L-LPINK = 
Light Pink 
L-LSTRAW = 
Light Straw 
Lens 
L-27K = 
2700K dichroic 
filter 
L-DAY = 
Daylight Lens 
L-SPINK = 
Surprise Pink 
Lens 
L-PLAV = Pale 
Lavender Lens 
L-HEX= Hex 
Cell Louver 
For additional options please consult factory. 
Matte white is recommended for self flanged reflectors