Hunter Universal Fan & Light Remote Control
Models 27224, 27210
Ratings:  
120 VAC, 60 Hz,1.0 Amp Fan  
Receiver Weight: 6 oz.
 
300 Watts incandescent light
Read and Save these Instructions
Caution: Risk of Electrical Shock!
All wiring must be performed in accordance with national and local electrical 
codes. If you are unfamiliar with the wiring codes, you should use a 
qualified electrician. 
To avoid overheating and possible damage to other equipment, do not 
install to control a receptacle, fluorescent light fixture, motor operated 
appliance, or transformer-supplied appliance. Use only to control one 
paddle-blade ceiling fan and incandescent light fixture.
Notes:
1. This device complies with Part 15 of the FCC Rules. Operation is subject to the fol-
lowing two conditions: (1) this device may not cause harmful interference, and (2) this 
device must accept any interference received, including interference that may cause 
undesired operation.
2. Industry Canada: Operation is subject to the following two conditions: (1) this device 
may not cause interference, and (2) this device must accept any interference, including 
interference that may cause undesired operation of the device.
3. This equipment has been tested and found to comply with the limits for a Class 
B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to 
provide reasonable protection against harmful interference in a residential installation. 
This equipment generates, uses and can radiate radio frequency energy and, if not 
installed and used in accordance with the instructions, may cause harmful interference 
to radio communications. However, there is no guarantee that interference will not 
occur in a particular installation. If this equipment does cause harmful interference to 
radio or television reception, which can be determined by turning the equipment off 
and on, the user is encouraged to try to correct the interference by one or more of the 
following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the 
receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
4. In the case of a power outage, the fan and light connected to this remote will turn off 
and remain off after the power resumes. 
5. For use only with electrically reversible ceiling fans rated at 1.0 amp or less, and fan 
incandescent light kits rated at 300 watts or less.
6. Not for use with shaded-pole motors. Not recommended for use with the Hunter 
Original®. For Hunter Original® series fans, use Hunter control model numbers 27187, 
22691, or 27189.
7. Medium and Low fan speeds are determined by the control and thus may vary from 
the factory settings due to normal motor variations.
8. For use with Hunter Hanging systems (excludes Hunter Original) on angled ceilings 
up to 34 degree pitch ceilings.
9. Not for use in applications where the fan does not have a wall switch
Any changes or modifications to this equipment not expressly approved by Hunter Fan 
Company will void the user’s authority to operate the equipment. 
Before Installing the Control:
1. Use the pull chain switch to set the fan speed to the HIGH 
position before installation. Do not use the pull chain to change 
the fan speed after installation, as damage to your ceiling fan or 
universal control may result. The speed of the fan should only be 
changed by the Hunter control.
2. Set the ceiling fan light kit to the ON position before installa-
tion. The light level should only be changed by the Hunter control. 
Receiver Installation:
1. Disconnect power to the ceiling fan and light kit at the main electrical panel. Remove 
fuse or move circuit breaker to the OFF position.
2. IMPORTANT! Before installing this control, Change the position of the jumpers in 
the transmitter and the DIP switches in the receiver. Be sure the position of the jumper 
in the transmitter matches the position of the DIP switches in the receiver. If they don’t 
match, the controller will not function. Select different combinations of settings to 
prevent misoperation due to other remote control fans.
3. IMPORTANT! If your ceiling fan light kit is using incandescent bulbs, then slide the 
CFL / INC switch to the INC position. Refer to Figure 1. If your ceiling fan light kit is 
using compact fluorescent light bulbs (CFL), then slide the CFL / INC switch to the 
CFL position. NOTE: When the switch is in the CFL position, the dimming feature is 
disabled, and you will not be able to dim the light bulbs. This feature is to protect both 
your bulbs and your receiver as CFL bulbs are not able to dim and will malfunction if 
dimming is attempted.
4. Determine your ceiling fan mounting type (Figure 2). Most installations will be one of 
these four types: Canopy Hanger, Hunter Hands-Free
TM
 Canopy, Low Profile Styles I 
and II, or Bracket Hanger.
5. Install the ceiling fan according to its instructions, up to the point of making the 
electrical connections. Connect receiver to ceiling fan according to the mounting type 
as instructed in Figure 2.
6. If the fan is already installed, turn the power OFF at the main electrical panel. 
Reverse the installation procedure according to the fan instructions, to the point of 
disconnecting the fan wiring. Connect the receiver to the ceiling fan according to the 
mounting type as instructed in Figure 2.
7. Use the 2 large wire connectors supplied to connect the receiver and house wiring, 
then use the 3 small wire nuts supplied to connect the receiver and ceiling fan wiring. 
Refer to the Wiring Diagram in Figure 3.
8. Be sure the antenna is positioned securely, so it can not interfere with the ceiling 
fan motor. Refer to Figure 2. Do not modify or damage the antenna wire, as control 
performance may be reduced. After securing the receiver, antenna, and wiring, finish 
hanging the ceiling fan according to its instructions.
9. Restore power at main electrical panel.
Transmitter Installation:
1. Install the 12 volt alkaline battery (A23 or equivalent) inside the hand-held transmit-
ter, after setting the dip switches to match the dip switches in the receiver.
2. Mount the remote holder over the ceiling fan’s wall switch using the existing wall 
plate screws. Refer to Figure 4.
3. The transmitter can be placed on the remote holder for convenience or safekeeping.
Fan Installation Types:
NOTE: Some fans may have considerable excess lead wire. For easier canopy 
installation, cut the excess wire leaving a minimum of 6 inches  remaining. Restrip the 
fan lead wires 1/2 inch. Place remaining excess wire into the ceiling electrical box as 
needed.
Canopy Hanger (Fig. 2-A): Place receiver in canopy. Connect wiring as shown in Fig. 
3. Extend antenna through one of the ceiling plate openings (approximately 3–6˝).
Hunter Hands-Free™ Canopy (Fig. 2-B): Connect wiring as shown in Figure 3. Place 
receiver inside mounting bracket. Extend antenna above the ceiling mounting bracket 
(approximately 3–6˝).
Low Profile Style I (Fig. 2-C): Secure receiver to the fan plate above the motor with UL 
listed cable ties (not included). Connect wiring as shown in Figure 3. Extend antenna 
through one of the ceiling plate openings (approximately 3–6˝).
Low Profile Style II (Fig. 2-D): Secure receiver to the ceiling mounting bracket with UL 
listed cable ties (not included). Connect wiring as shown in Figure 3. Extend antenna 
above the ceiling mounting bracket (approximately 3–6˝).
Bracket Hanger (Fig. 2-E): Starting with the antenna wire, slide receiver inside 
mounting bracket. If a ground wire mounting screw prevents the receiver from sliding 
into the bracket, move ground wire and screw to an unused hole at the top of the 
bracket or secure with a canopy mounting screw. The bracket must remain properly 
grounded. Connect wiring as shown in Figure 3. Extend antenna above the receiver 
(approximately 5–8˝).
Cable Tie Routing for Low Profile Fans (Figs. 2-C, 2-D): Insert cable tie through open-
ings as shown. DO NOT insert the cable 
tie through the inside of the receiver. The cable tie 
can be placed across the length or width of the 
receiver to best match your fan installation type.
Fig. 2-A
Fig. 2-B
Figure 2
Ceiling
Plate
Receiver
Canopy
Antenna
Ceiling
Plate
Receiver
Canopy
Antenna
Ceiling
Bracket
Receiver
Receiver
Placement
On Motor
Fan
Motor
Motor
Mounting
Plate
Antenna
Ceiling
Bracket
Receiver
Fan Body
Antenna
Antenna
Receiver
Canopy
Bracket
Canopy
Hands-Free
TM
Canopy
Low Profile I
Low Profile II
Bracket Hanger
Fig. 2-C
Fig. 2-D
Fig. 2-E
1. Light Operation: 
• Turn ON wall switch, the light will turn ON at maximum brightness. 
• Press and quickly release the light key on the hand held remote to turn the light OFF 
or ON. (Light will come ON at maximum brightness.)
• Press and hold the light button for more than 1 second to turn the light ON and 
decrease from maximum brightness to OFF.
• Release the light button when the desired light level is reached.
• Continue to hold the light button to repeat the cycle. (Maximum–light level decrease–
OFF)
• While the light is ON, holding the light button will decrease the light brightness.
• Turning the light OFF resets the dimming function. The next press of the light button 
will start at maximum brightness.
2. Fan Operation:
• Press the High, Medium, or Low speed buttons to turn the ceiling fan ON at the 
desired speed.
• Press the fan OFF key to turn the ceiling fan OFF.
For best fan operation: Start the fan on High, and then select the desired speed.
AC
Power
In
Light
Kit
Red
Black
White
Fan
White/Neutral
Black/Hot
Common
Antenna
Figure 3
Wiring Diagram
 TROUBLESHOOTING
HUNTER FAN COMPANY CONTROL LIMITED WARRANTY
The Hunter Fan Company makes the following limited warranty to the original purchaser of the Control (“Control”): Your Control is warranted to be free from defects in material and 
workmanship for a period of one year from the date of sale. If the Control malfunctions or fails within the warranty period due to a defect in material or workmanship we will replace 
it free of charge. IF THE ORIGINAL PURCHASER CEASES TO OWN THE CONTROL, THIS WARRANTY AND ANY IMPLIED WARRANTY, INCLUDING BUT NOT LIMITED TO 
ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE VOIDED. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS 
WARRANTIES. THE DURATION OF ANY IMPLIED WARRANTY, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR 
A PARTICULAR PURPOSE, IN RESPECT TO ANY CONTROL, IS EXPRESSLY LIMITED TO THE PERIOD OF THE EXPRESS WARRANTY SET FORTH ABOVE FOR SUCH 
CONTROL. This warranty excludes malfunctions or failures which were caused by repairs by persons not authorized by us, mishandling, improper installation, modifications, or dam-
age to the Control while in your possession, or unreasonable use. This warranty does not apply to batteries or to deterioration or damage to the product caused by the use of faulty 
batteries. To obtain a replacement, return your Control postage prepaid along with proof of purchase to Hunter Fan Company Service Department at 7130 Goodlett Farms Pkwy. 
#400, Memphis, Tennessee 38016. IN NO EVENT SHALL HUNTER FAN COMPANY BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES. SOME STATES DO NOT 
ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS OR THE EXCLUSION OR LIMITATIONS OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE 
ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS 
WHICH VARY FROM STATE TO STATE.
Symptom
Figure 1
Transmitter Back
Receiver Back
DIP Switches
Antenna
Jumpers
CFL/INC Switch (Shown in 
incandescent position)
Possible Causes
Solution
1. No functions operate.
2. Operates only at close range.
3. Inconsistent operation. 
Main Power not restored.
Replace fuse. Turn ON circuit breaker. Turn ON wall switch.
Signal blocked from reaching receiver.
Extend antenna into ceiling box, or move it for better reception. 
Signal partially blocked from reaching 
receiver.
Change dip switch settings to a different code in both
Transmitter and Receiver.
Fan pull chain not set to High.
Light pull chain not set to ON.
Receiver wiring incorrect.
Transmitter and receiver dip switches do 
not match.
Battery too weak.
Set fan pull chain to High speed.
Set light kit to ON. 
Verify wiring connections.
Set transmitter and receiver to same dip switch setting.
Replace with new, 12 volt alkaline battery.
Battery too weak.
Replace with new, 12 volt alkaline battery.
RF interference.
Continuing RF interference.
Extend antenna into ceiling box, or move it for better
reception.
Turn OFF wall switch for 5 seconds, then turn back ON.
44023-01 03/04/2011
Printed in China and Taiwan
CFL
4 3 2 1
4 3 2 1
4 3 2 1
4 3 2 1
4 = off (apagado)
3 = on (encendido)
2 = on (encendido)
1 = on (encendido)
4 = off (apagado)
3 = on (encendido)
2 = off (apagado)
1 = on (encendido)
Fan High
Fan Medium
Fan Low
Fan Off
Light
Figure 4