1. Parts Identification
3. Parts List
2.Wiring Diagram
PAGE
1~12
14~19
13
Ceiling Mount Ventilating Fan
Version A
SPECIFICATIONS
FV-05/08/11VQ3,FV-15VQ4
Version B
WARNING
This service information is designed for experienced repair technicians only and is not designed for use by
the general public. It does not contain warnings or cautions to advise non-technical individuals of potential
dangers in attempting to service a product. Products powered by electricity should be serviced or repaired
only by experienced professional technicians. Any attempt to service or repair the product or products dealt
with in this service information by anyone else could result in serious injury or death.
IMPORTANT SAFETY NOTICE
There are special components used in this equipment which are important for safety. These parts are
marked by
in the Schematic Diagrams, Exploded Views and Replacement Parts List. It is essential
that these critical parts should by replaced with manufacturer s specified parts to prevent shock, fire
or other hazards. Do not modify the original design without permission of manufacture.
(North American Market)
WhisperCeiling
TM
Duct
diameter
Noise
Power
consumption
Speed
Air deliver at
0.1"WG
Weight
(inches)
(sones)
(W)
(rpm)
(cfm)
Ib.(k
g)
Model No.
Air
direction
V
Hz
<0.3
13.0
820
FV-05VQ3
Exhaust 120 60
FV-11VQ3
50
11.7(5.3)
FV-08VQ3
4
0.3
23.0
730
80
12.6(5.7)
4
14.1(6.4)
4
0.8
31.0
810
Sepcifications are based on HVI standard.
110
13.0(5.9)
FV-15VQ4
6
0.6
32.0
670
150