Install Discharge Chute Crank 
1. Remove the cover from the gear assembly on the 
discharge chute.
2. Release the lock teeth on the gear assembly with 
your finger and rotate the discharge chute 90
°
 
left.
3. Remove and save the hairpin from the control 
assembly underneath the control panel.
NOTE: Do not remove the pin installed on the chute 
rod. 
NOTE: To ensure the discharge chute follows its full 
range of travel, make sure the control lever is pushed 
all the way to the left before installing and pinning the 
chute rod.
4. Align the holes on the end of the chute rod with 
the mark on the gear assembly and slide the end 
without a pin through the gear assembly, through 
the loop on the chute lock cable and into the hex 
hole in the control assembly.
IMPORTANT: The loop will prevent the control cable 
from contacting the engine or muffler guard. If the loop 
gets damaged, loosely tie the cable to the control rod.
NOTE: After the chute rod has been inserted through 
the hex hole in the control assembly, placing the unit in 
the service position (see Service Position on page 19
will ease alignment and installation of the hair pin.
5. Secure the chute rod to the control assembly with 
the hair pin removed in step 3 using the proper 
hole location as shown in Figure 7. Insert the hair 
pin with the loop end to the left of the chute rod so 
the control assembly follows a full range of travel.
Figure 5
1. Mounting Hardware
2. Discharge Chute
3. Chute Pedestal
4. Discharge Chute 
Ring
OS7040
OS7045
Figure 6
1. Chute Rod
2. Gear Cover
3. Control Assembly
4. Hair Pin
OS7060