carbon Monoxide (co) Detector/ smoke Detector
 
       Carbon Monoxide (CO) detector(s) installed and in working 
order.
 
       Smoke detector(s) installed and in working order.
Placement
 
     Required permits have been obtained.
 
    Generator placed in an area free from Carbon Monoxide 
(CO) buildup. See Placement of Standby Generator to 
Reduce the Risk of Carbon Monoxide Poisoning.
 
    Generator placed in an area compliant to NFPA 37. See 
Placement of Standby Generator to Reduce the Risk of 
Fire.
 
    Generator placed in an area free from water damage. See 
Other General Location Guidelines.
 
    Generator placed in an area free from utility and other 
home systems. See Other General Location Guidelines.
 
    Generator placed in a debris free zone. See Other General 
Location Guidelines.
 
     Generator placed on flat ground with provisions for water 
drainage.See Other General Location Guidelines.
fuel
 
    Generator is connected to fuel source with steel flexible 
fuel line, has no fuel leaks and conforms to local codes. See 
The Gaseous Fuel System.
 
    Proper fuel pressure has been measured with all gas 
appliances operating. See The Gaseous Fuel System.
 
    Fuel system has been configured for the proper fuel 
supply: Natural gas (NG) or liquefied petroleum ( LP). See 
Fuel Conversion.
 
     Fuel type: (circle one)      nG     LP
 
     Fuel pipe size used: (circle one)    3/4”    1”    1-1/4”      1-1/2” 
see nfPa 54.
 
     Fuel pressure at fuel inlet port with generator on and at 
full load and all gas appliances turned on and operating 
____________________.
electrical
 
    Generator neutral is connected to Automatic Transfer 
Switch. See Generator AC Connection System.
 
    
Generator is grounded. See Grounding the Generator and 
NFPA 70,NEC.
 
    Generator is connected to the transfer switch with the 
specified wiring. See Utility Circuit Connection and 
Transfer Switch Communication.
 
    Generator is connected to the transfer switch with the 
specified wiring. #18AWG twisted pair wiring from the 
generator control panel to the transfer switch is installed 
in a separate conduit from high voltage wires unless 
the insulation rating on all wiring is rated for 600V See 
Transfer Switch Communication.
 
    Dipswitches in most transfer switches must be set to 
correspond to the wattage of the generator. See Transfer 
Switch Operator/Installation Manual.
operation
 
    Cold weather kit is installed in temperatures below 
XX°F 
(5°C)
. See Cold Weather Kit.
 
    Correct battery type is installed and fully charged. See 
Final Installation Considerations.
 
    Generator engine oil level is at full mark. See Final 
Installation Considerations.
 
    Circuit breaker is in the ON position. 
 
    Utility was shut off to test the operation of generator and 
transfer switch. Note any fault codes and make corrections 
as required.
 
    AC Voltage Output___________________________.
 
    Frequency Output___________________________.
installation checklist - Ge home Generator systems
Proper installation of the home generator requires the completion of the following tasks:
owner information
Name: _____________________________________________
Address: ___________________________________________
___________________________________________________
Phone/e-mail: _______________________________________
unit information
Generator Model: ____________________________________
Generator Serial Number: _____________________________
installing contractor information
Name: _____________________________________________
Address: ___________________________________________
___________________________________________________
Phone/FAX: _________________________________________
Electrician:  _________________________________________
Signature: __________________________________________
Plumber:  ___________________________________________
Signature:  _________________________________________
inspector information
Name: _____________________________________________
Address: ___________________________________________
___________________________________________________
Title: _______________________________________________
Inspection Date: _____________________________________
this generator has been installed per the manufacturer’s 
instructions:
Installing Contractor Signature:  ______________________________