Generac QT04854JNAX User Manual

Page of 6
OPERATING DATA
KW RATING (LP/NG)
48/48
ENGINE SIZE
5.4 Liter
GENERATOR OUTPUT VOLTAGE/KW - 60Hz
kW LP
AMP
CB Size
120/240V, 1-phase, 1.0 pf
120/208V, 3-phase, 0.8 pf
120/240V, 3-phase, 0.8 pf
277/480V, 3-phase, 0.8 pf
48
48
48
48
200
166
144
72
200
175
150
80
ENGINE FUEL CONSUMPTION 
(Natural Gas) (Propane)
Exercise cycle
25% of rated load
50% of rated load
75% of rated load
100% of rated load*
For Btu content, multiply ft
3
/hr x 2520 (LP) or ft
3
/hr x 1000 (NG)
Natural Gas
(ft
3
/hr.)
95
204
392
547
756
Propane
 
(gal/hr.)
 
cu ft/hr
 
2.0
 
38
 
2.16
 
82
 
4.14
 
157
 
5.8
 
220
 
7.96
 
302
ENGINE COOLING
Air flow 
(inlet air including alternator and combustion air)
 
ft
3
/min.
System coolant capacity
 
US gal.
Heat rejection to coolant
 
BTU/hr.
Max. operating air temp. on radiator
 
°C (°F)
Max. ambient temperature
 
°C (°F)
4350
3.0
186,000
60 (150)
50 (140)
COMBUSTION AIR REQUIREMENTS
Flow at rated power 60 Hz
 
cfm
163
SOUND EMISSIONS IN DBA
Exercising at 7 meters
Normal operation at 7 meters
63
68
EXHAUST
Exhaust flow at rated output 60 Hz
 
cfm
Exhaust temp. at muffler outlet
 
°F
414
1025
ENGINE PARAMETERS
Rated synchronous RPM
 
60 Hz
1800
POWER ADJUSTMENT FOR AMBIENT CONDITIONS
Temperature Deration
3% for every 10 °C above - °C
1.65% for every 10 °F above - °F
Altitude Deration
1% for every 100 m above - m
3% for every 1000 ft. above - ft.
25
77
183
600
*  Refer to "Emissions Data Sheets" for maximum fuel flow for EPA and SCAQMD permitting purposes. 
RATING: 
 All three phases units are rated at 0.8 power factor. All single phase units are rated at 1.0 power factor. STANDBY RATING: Standby ratings apply to installations served by a 
reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage.  There is no overload capability for this rating. Ratings are in accordance with 
ISO-3046-1. Design and specifications are subject to change without notice.
KW rating is based on LPG Fuel and may derate with natural gas.
Generac
®
 QuietSource
®
 Series Standby Generator - 48 kW
®