CHANGING THE SPARK PLUG
Replace the spark plug each year, regardless of how many hours the 
generator has been run. Use a NGK BPR7HS that has be gapped to 
.030” (.76mm). To replace the spark plug:
1.  Remove  the  spark  plug  cover  on  the  top  right  side  of  the 
generator, just below the handle (Figure 12).
2.  Carefully  pull  the  spark  plug  lead  from  the  spark  plug.  Use  a 
socket wrench to remove the spark plug. 
3.  Install  the  new  spark  plug  into  the  cylinder  head.  Tighten  the 
spark plug to 15 ft/lb.
4.  Replace the spark plug lead, making sure it is fully seated.
5.  Replace the spark plug cover.
Figure 12 - Replace Spark Plug
SPARK PLUG
LOCATION
TRANSPORTATION AND STORAGE
Transport or store the generator only if it has cooled completely.  Make 
sure the fuel valve and the vent on the fuel cap are both in the OFF 
(“O”) position.
It is important to prevent gum deposits from forming in essential fuel 
system  parts  such  as  the  carburetor,  fuel  hose  or  tank  during  long-
term  storage.  Also,  experience  indicates  that  alcohol-blended  fuels 
(called  gasohol,  ethanol  or  methanol)  can  attract  moisture,  which 
leads to separation and formation of acids; these acids can damage 
the fuel system of an engine while in storage.
To avoid engine problems, the use of a commercial fuel stabilizer prior 
to  storage  is  recommended.  Follow  the  manufacturer’s  instructions 
when adding the fuel stabilizer.
If the generator is going to be stored for more than six (6) months, the 
generator should be prepared as follows:  
1.  Remove all gasoline from the fuel tank.
2.  Start and run engine until engine stops from lack of fuel or open the 
valve  on  carburetor  bowl  (Figure  13),  and  allow  gasoline  to  drain 
down tube into a receptacle. Discard appropriately. Be sure to close 
the valve once the gasoline has drained.
Figure 13 - Carburetor Drain Valve
CARBUREATOR DRAIN
VALVE LOCATED BEHIND
AIR INTAKE
TURN VALVE COUNTER-
CLOCKWISE TO DRAIN FUEL,
CLOCKWISE TO CLOSE
3.  While  engine  is  still  warm,  drain  oil  from  crankcase.  Refill  with 
recommended grade.
4.  Remove spark plugs and pour about 1/2 ounce (15 ml) of engine 
oil  into  the  cylinders.  Cover  spark  plug  hole  with  rag.  Pull  the 
starting rope several times to coat the cylinder walls with engine 
oil.
5.  Install and tighten the spark plug.
6.  Clean the generator outer surfaces. Check that cooling air slots 
and openings on generator are open and unobstructed.
7.  Store the unit in a clean, dry place.
Do not store gasoline from one season to another.
If possible, store the unit indoors and cover it to give protection from 
dust and dirt.