Figure 3 - Control Panel
13
14
15
16
17
18 19
20
PRE-USE CHECK
Prior to starting the generator and adding loads, perform the following 
tasks:
1.  Make  sure  the  generator  in  on  a  firm,  level,  non-combustible 
surface with at least five (5) feet of clearance on all sides.
‹ 
 Never operate in an enclosed area or indoors! 
NEVER use in the home, in a vehicle, or in 
partly enclosed areas such as garages, even 
if doors and windows are open! ONLY use 
outdoors and far from open windows, doors, 
vents, and in an area that will not accumulate 
deadly exhaust.
‹ 
 The engine exhaust fumes contain carbon 
monoxide, which you cannot see or smell. 
This poisonous gas, if breathed in sufficient 
concentrations, can cause unconsciousness 
or even death.
‹ 
 Adequate, unobstructed flow of cooling and 
ventilating air is critical to correct generator 
operation. Do not alter the installation or 
permit even partial blockage of ventilation 
provisions, as this can seriously affect safe 
operation of the generator. The generator 
MUST be operated outdoors.
‹ 
 This exhaust system must be properly 
maintained. Do nothing that might render the 
exhaust system unsafe or in noncompliance 
with any local codes and/or standards.
‹ 
 The manufacturer recommends installing 
a battery operated carbon monoxide alarm 
indoors, according to the manufacturer's 
instructions.
‹ 
 NEVER use in the home, or in partly enclosed areas 
such as garages, campers or trailers. ONLY use 
outdoors and far from open windows, doors, vents.
2.  Remove the fuel cap and check the fuel level.  If fuel is needed, 
see the section “FUELING THE GENERATOR”.
3.  Remove  the  left  side  service  cover  and  check  the  oil  level  by 
removing the oil filler cap. The oil level should be to the bottom 
of the threads on the oil fill pipe.  If oil is needed, see the section 
“ADDING ENGINE OIL”.
4.  Replace and secure the left side service cover.
5.  Make sure there are no loads connected to the generator.
6.  The  National  Electric  Code  (NEC)  requires  the  frame  and 
external electrically conductive parts of the generator be properly 
connected to an approved earth ground. Proper grounding of the 
generator will prevent electrical shock in the event of a ground 
fault condition in the generator or in connected electrical devices.  
Proper  grounding  also  helps  dissipate  static  electricity,  which 
often builds up in unguarded devices. 
7.  Local electrical codes may also require proper grounding of the 
generator.
‹
 Starting the generator with accessories 
connected to the 120 VAC outlets will damage 
the generator and the connected devices.
Operation